PCI-DB.com
  1. Driver
  2. Motherboard
  3. Intel R2000GL Server System IDA/OFU Firmware 2.04/2.01/1.22/1.13

Intel R2000GL Server System IDA/OFU Firmware 2.04/2.01/1.22/1.13 Download

Posted at November 21, 2024 by PCI-DB Team

Install Driver Automatically
Device NameIntel R2000GL Server System IDA/OFU Firmware 2.04/2.01/1.22/1.13
CategoryMotherboard
ManufacturerIntel
File Size46 MB
Supported OSOS Independent

Intel R2000GL Server System IDA/OFU Firmware 2.04/2.01/1.22/1.13 Description

Versions:

- BIOS : 02.04.0003
- ME : 02.01.07.328
- BMC : 01.22.6890
- FRUSDR : 1.13

Changes in BIOS R02.04.0003:

- Update: Integrate the new SSID(0x355B) of Intel Ethernet Controller X540 module in BIOS for supporting the new EEPROM of this IOM.

Changes in ME 2.01.07.328:

- Fixed: Platform is not able to power on properly after being shut down by NM Policy
- Fixed: Global platform power consumption reported by NM Statistics in S5 is incorrect
- Fixed: OOB (out-of-band) stress test by issuing the wrong username may cause connection to be unavailable
- Fixed: Shutdown action can be interrupted by cold reset when volatile NM policy is in use

Changes in BMC 01.22.6890:

- Fixed: IPMB Bridging commands to a Satellite controller doesn't work
- Fixed: The result of IPMI raw command 20 c0 71 00 02 00 00 shows telnet can be supported.
- Fixed: The satellite FW updating status is 00 while updating HSBP FW.
- Fixed: i2c-adapter i2c-7: Arbitration lost on data transmission
- Fixed: Remote KVM video have some dirty mouse cursor under linux system
- Fixed: The System Fan 5 spining in 100% speed on S2400BB Platform after updated the BMC to 1.21.6038.
- Fixed: FW update will fail with OS based utility (OFU), failure rate is 20% with USB mode and 40% with KCS mode.
- Fixed: BMC code issue for fan detection on S2600CO.
- Fixed: EWS can't interpret SmaRT/CLST event
- Fixed: S2600GZ/GL EWS_update tool fail with SUP S2600GZ_GL_EFI_BIOS02030003_ME20107328_BMC1216038_FRUSDR113
- Fixed: Openssl update (see TA-1065)
- Fixed: IPv6 can't get IP address via DHCP server.
- Fixed: S4600LH P3 LVDIMM voltate reading is 1.5V sometimes during system booting up
- Fixed: HSC firmware not updating with BMC 1.21.6038;
- Fixed: BMC Hangs upon the first A/C Power On of the board. Subsequent A/C power cycles, the BMC boots.
- Bundled the new PSU fw for PSSF162202A.
- Bundled the new PSU fw for "DPS 750AB 32A".
- Set RMM4 DMN speed to 100Mbps on half width products




  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Intel Drivers

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.