Install Driver AutomaticallyDevice Name | Intel S1200RPL Server Board Firmware 01.02.0004 |
---|---|
Category | Firmware |
Manufacturer | Intel |
File Size | 21.6 MB |
Supported OS | Windows All |
- Signed driver check test fails due to an unknown device found in Windows 2012 WHQL (Windows Hardware Quality Labs) certification.
- When the ME put into Recovery mode using the Recovery jumper and host performs transition from Sx to S0 additional unexpected global platform reset appeared.
- Power Statistics after platform shutdown by policy are not valid
- Factory Presets and AIM, OCS and OCP MFS files are not readable using MESDC or Diagnostic Service.
- Dynamic Core Allocation: SetTotalPowerBudger does not park cores.
- Disable NM IPMI command does not stop limiting power (NM S0only SKU with OEM thermal reading and SUSEx11x64 )
- ME is not responding after Unconditional Power Down.
- Unexpected ME reset happens after repeated power state changes.
- Several lines are doubled in LPTAB_NM.XML
- NM memory power capping occasionally fails outside 2.5% range.
- Superfluous CPU/MEM power requests on PECI during Sx state.
- The ME Recovery IPMI command many not always work.
- The OS ACPI PState may differ by 2 from what was set by Node Manager.
- Missing reading police is not triggered in the CPU domain.
- After creating policy the min. value in statistics gathered per-policy-Id is always 0 W.
- NM does not limit power if cores are disabled from BIOS setup
- The loss of all power readings in domain: 0, 1 or 2 is signaled with only one NM Health Event.
- MESDC: SUSRAM - Entry Format is unknown
- No "Firmware Update In Progress" bit set in FW Status register during online update.
- Change Intel RMM in EWS into RMM Dedicated Mgmt.
- The LCD Screen display is not clear while scrolling error events.
- LAN leash lost event is shown during DC cycle testing.
- Px DIMM Thrm Mrgn and Px DIMM Thrm Trip not decoding DIMM number correctly in the Embedded Web Server SEL text log.
- Embedded Web Server SEL text log not decoding BIOS update versions correctly.
- There are assert events for Mem Err Sensor 0x28 - 'DIMM Thrm Mrgn 1' sensor and 'SPS FW Health' sensor after updating ME firmware.
- Fixed the issue of System status LED show green blinking when unplug the front panel
- BIOS: 01.02.0004
- ME: 03.00.04.164
- BMC: 1.05.4775
- FRUSDR: 1.04
It is highly recommended to always use the most recent driver version available.
Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.
Device Type: Graphics Board File Size: 355.1 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 300 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 300 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 148.1 MB Windows 8.1 64 bit
Install DriverDevice Type: Graphics Board File Size: 111.5 MB Windows 8
Install DriverDevice Type: Graphics Board File Size: 25.3 MB Windows 7 64 bit
Install DriverDevice Type: Graphics Board File Size: 49.8 MB Windows 7 64 bit
Install DriverDevice Type: Graphics Board File Size: 355.1 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 117 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 354.1 MB Windows 10 64 bit
Install DriverFind Missing Drivers
Recent Devices
Recent Drivers
© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.