PCI-DB.com
  1. Driver
  2. Other Drivers Tools
  3. Yamaha MTX Editor Utility 1.2.1/Firmware 1.2.0

Yamaha MTX Editor Utility 1.2.1/Firmware 1.2.0 Download

Posted at March 28, 2024 by PCI-DB Team

Install Driver Automatically
Device NameYamaha MTX Editor Utility 1.2.1/Firmware 1.2.0
CategoryOther Drivers Tools
ManufacturerYamaha
File Size62.7 MB
Supported OSWindows 7 ,Windows 7 64 bit ,Windows 8 ,Windows 8 64 bit

Yamaha MTX Editor Utility 1.2.1/Firmware 1.2.0 Description

This zip file includes the following:

- MTX Editor V1.2.1  for Windows 7/Windows 8
- MTX3 Firmware V1.20
- MTX5-D Firmware V1.20
- EXi8 Firmware V1.20
- EXo8 Firmware V1.20
- XMV series Firmware V1.20
- Dante Firmware Update Manager V1.4.5.7
- MTX5-D Dante Firmware V3.7.1.10-3.4.9.3-1.2.1
- XMV series Dante Firmware V3.7.1.10-3.4.9.3-1.2.1

MTX Editor 1.1.2

New Functions
- The MTX5-D now supports the MY4-AEC card.
- The MTX5-D now features a POST ON insert function for input channels 1-16, for use with the DUGAN-MY16 card. Modification of the DUGAN-MY16 card's default settings requires an external application.
- The choice of available subnet masks has been extended to increase network IP address range compatibility.
- A blue button for displaying possible solutions to Alerts has been added to the “Alert” tab.
- The digital input sensitivity of XMV amplifiers can now be changed in the "Device" tab.

Fixed Bugs

- Solved a problem when SLOT was chosen as a port for an input channel, the signal indicator is now correctly displayed on the port/external device parameter access button.
- Solved a problem when if the system name had a comma (,), cell fields may be shifted in an acquired alert log (csv file).
- Solved a problem when MTX Editor could not recognize network devices if the host computer had two or more IP addresses assigned to the same network adaptor.
- Solved a problem when the "Digital Control Panel" dialog, the "Wireless DCP" dialog and the "GPI" dialog, displayed the parameter name for STIN1 incorrectly if 3L/3R is assigned to 'MONO x 2' in the 'MTX Configuration' dialog.

Improvements

- Library Store and Recall functionality has been added to the "Digital Control Panel" dialog and the "Wireless DCP" dialog.
- The operation of the current preset display box in the toolbar area has been changed. Clicking in the box will now overwrite the current Preset to allow quicker updating of the current Preset.
- Right-click level (0,-3,-6, -infinity dB) and on/off shortcuts have been added to the “Matrix” screen.
- Right-click level (0,-3,-6, -infinity dB) shortcuts have been added to the effect selection buttons in the “Effect” screen.
- An [All Clear] button for Events has been added to the "Scheduler" dialog box.
- The Password field has been renamed to “PIN”.
- Channel navigation has been added to the "Input Patch" and the "Output Patch" dialog boxes.
- The “CHANNEL EDIT” screen has been separated into dedicated “INPUT” and “OUTPUT” screens.
- The Input Channel parameter edit screen now displays eight channels in the "MAIN" screen.
- The type of audio connection format (YDIF, Dante or Analog) and device ID number for any connected XMV amplifier and EXo8 is now indicated in the Output Channel parameter edit screen. The display is also now grouped by connection format.
- In addition to the system clock of the host MTX Editor computer, the current time information of connected system is now displayed in the "Clock" dialog box.
- Right click copy and paste parameter functionality has been added to “XMV” and “EXo8” screens.
When one or more digital control panel(s) (DCP) is not connected to an MTX, but the panel exists in the project file, the DCP icon in the “Project” screen is grayed out.

MTX3 Firmware 1.20

New Function
-The choice of available subnet masks has been extended to increase network IP address range compatibility.

Fixed Bugs

Solved a problem when immediately after startup, a NOTIFY command parameter was sent to an external controller.
- Solved a problem that caused the compressor of STIN2 to act in a stereo manner when the channel was set to MONOx2 in the “MTX Configuration” dialog box.
- Solved a problem when a log may be incorrectly retrieved in the "Get Log" dialog box of MTX Editor.
- Solved a problem when the IP SETTING of a device was set to PC mode (DIP switch 6 down), with an IP address other than 192.168.0.x , and then the IP SETTING was changed to UNIT ID mode (DIP switch 6 up), the IP address of the device was not set correctly to 192.168.0.(UNIT ID).

MTX5-D Firmware 1.20

New Functions
- Now supports the MY4-AEC card.
- Now supports the DUGAN-MY16 card.
- The choice of available subnet masks has been extended to increase network IP address range compatibility.
- Now supports the “Identify device function” of Dante Controller.

Fixed Bugs

- Solved a problem when immediately after startup, a NOTIFY command parameter was sent to an external controller.
- Solved a problem when the SRC setting of the MY8-AE96S card was not saved to MTX5-D.
- Solved a problem that caused the compressor of STIN2 to act in a stereo manner when the channel was set to MONOx2 in the “MTX Configuration” dialog box.
- Solved a problem when a log may be incorrectly retrieved in the "Get Log" dialog box of MTX Editor.
- Solved a problem when the IP SETTING of a device was set to PC mode (DIP switch 6 down), with an IP address other than 192.168.0.x , and then the IP SETTING was changed to UNIT ID mode (DIP switch 6 up), the IP address of the device was not set correctly to 192.168.0.(UNIT ID).

XMV Firmware 1.20

New Functions
- The choice of available subnet masks has been extended to increase network IP address range compatibility.
- Now supports the “Identify device function” of Dante Controller. (Dante models only)
- In addition to the existing -3dBFs input sensitivity setting, a -20dBFs option has been added for YDIF and Dante inputs. If -20dBFS is set from MTX editor, the digital input sensitivity will match that the analog input sensitivity.

Fixed Bugs

- Solved a problem when immediately after startup, a NOTIFY command parameter was sent to an external controller.
- Solved a problem when the Dante input patch of a XMV (Dante Model) was not correctly set if the UNIT ID of the device was changed.
- Solved a problem when the Dante input patch may be incorrect if synchronization was performed from MTX Editor and a XMV (Dante model) in the system was powered OFF, and then power to that XMV was turned ON.
- Solved a problem when the IP SETTING of a device was set to PC mode (DIP switch 6 down), with an IP address other than 192.168.0.x , and then the IP SETTING was changed to UNIT ID mode (DIP switch 6 up), the IP address of the device was not set correctly to 192.168.0.(UNIT ID).

EXi8/EXo8 Firmware V1.20

New Function
- The choice of available subnet masks has been extended to increase network IP address range compatibility.

Fixed Bugs

- Solved a problem when immediately after startup, a NOTIFY command parameter was sent to an external controller.
- Solved a problem when the IP SETTING of a device was set to PC mode (DIP switch 6 down), with an IP address other than 192.168.0.x , and then the IP SETTING was changed to UNIT ID mode (DIP switch 6 up), the IP address of the device was not set correctly to 192.168.0.(UNIT ID).

  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Yamaha Drivers

Yamaha SY85 USB-MIDI Driver 3.1.4 64-bit

Device Type: Audio Dj Gear File Size: 6.5 MB Windows XP 64 bit ,Windows Vista 64 bit ,Windows 7 64 bit ,Windows 8 64 bit ,Windows 8.1 64 bit ,Windows 10 64 bit

Install Driver

Yamaha SY85 USB-MIDI Driver 3.1.4

Device Type: Audio Dj Gear File Size: 6.4 MB Windows XP ,Windows Vista ,Windows 7 ,Windows 8 ,Windows 8.1 ,Windows 10

Install Driver

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.