PCI-DB.com
  1. Driver
  2. Motherboard
  3. Intel S1200V3RPL Server Board EFI Firmware 02.02.0005

Intel S1200V3RPL Server Board EFI Firmware 02.02.0005 Download

Posted at December 22, 2024 by PCI-DB Team

Install Driver Automatically
Device NameIntel S1200V3RPL Server Board EFI Firmware 02.02.0005
CategoryMotherboard
ManufacturerIntel
File Size22.5 MB
Supported OSOS Independent

Intel S1200V3RPL Server Board EFI Firmware 02.02.0005 Description

Versions:

- BIOS: R02.02.0005
- ME: R03.00.05.128
- BMC: 1.12.6784
- FRUSDR: 1.07

BIOS Changes in R02.02.0005:

- Fixed: RS25GB008/RS2PI008 RAID cards lost after S3 resume when it plugged into slot4/7.
- Fixed: The primary display option doesn't show in the MFG mode.
- Fixed: The "Internal Graphics" option displayed on BIOS Setup in MFG mode with no-graphic CPU.
- Fixed: NMI activated-system halted when three specific cards plugged into slot 4/6 and SAS_mod slot.
- Fixed: [x]incorrect message showed on POST that S1200RPL with two SATA ports @ 3Gbps and 4 SATA ports @6Gbps.
- Fixed: The onboard VGA would display after S3 when on board video was set to disabled in BIOS Setup.
- Disable ACPI S4 support

ME Changes in 03.00.05.128:

- Fixed: Bit Reserved16 in PCH Strap 15 is set incorrectly. This change in Flash Descriptor was introduced in previous release and reverted in this one.

BMC Changes in 1.12.6784:

- Fixed: Can't get the last entry when bmc event log is 100%
- Fixed: FW update will fail with OS based utility (OFU), failure rate is 20% with USB mode and 40% with KCS mode.
- Fixed: Sometimes FRB2 will be triggered after resuming from S3.
- Fixed: IPv6 can't get IP address via DHCP server.
- Fixed: After turning off then turning on the KVM/SSH/EWS/IPMI over lan services using Control BMC Services command, IPMI over lan service was still available.
- Fixed: In the EWS page "Security Settings", when click the "Enable" label of "SSH", "HTTP/HTTPS" and "IPMI over LAN", it will disable or enable the "Force HTTPS" option.
- Fixed: There are assert and de-assert events logged for sensor HDD Status- Device Faulty during DC cycle stress test.
- Fixed: There'll be a warning message for SEL is full after force update BMC
- Fixed: There's no SEL indicate the FW has been updated successfully when update BMC.
- Fixed: The SEL log event ID began at 512 the rather than starting from 1.
- Fixed: SEL log Timestamp message incorrect after AC cycle or BMC reset.
- Fixed: Updated to newer Openssl code version 0.9.8za .

FRUSDR Changes in 1.07:

- Update system Fan1 to FSC domain2, system Fan2 to domain0 in other chassis to align with schematic.




  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Intel Drivers

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.