Intel R1304RPSSFBN Server System EFI Firmware 02.02.0005 Description

Versions:

- BIOS: R02.02.0005
- ME: R03.00.05.128
- BMC: 1.12.6784
- FRUSDR: 1.07

BIOS Changes in R02.02.0005:

- Fixed: RS25GB008/RS2PI008 RAID cards lost after S3 resume when it plugged into slot4/7.
- Fixed: The primary display option doesn't show in the MFG mode.
- Fixed: The "Internal Graphics" option displayed on BIOS Setup in MFG mode with no-graphic CPU.
- Fixed: NMI activated-system halted when three specific cards plugged into slot 4/6 and SAS_mod slot.
- Fixed: [x]incorrect message showed on POST that S1200RPL with two SATA ports @ 3Gbps and 4 SATA ports @6Gbps.
- Fixed: The onboard VGA would display after S3 when on board video was set to disabled in BIOS Setup.
- Disable ACPI S4 support

ME Changes in 03.00.05.128:

- Fixed: Bit Reserved16 in PCH Strap 15 is set incorrectly. This change in Flash Descriptor was introduced in previous release and reverted in this one.

BMC Changes in 1.12.6784:

- Fixed: Can't get the last entry when bmc event log is 100%
- Fixed: FW update will fail with OS based utility (OFU), failure rate is 20% with USB mode and 40% with KCS mode.
- Fixed: Sometimes FRB2 will be triggered after resuming from S3.
- Fixed: IPv6 can't get IP address via DHCP server.
- Fixed: After turning off then turning on the KVM/SSH/EWS/IPMI over lan services using Control BMC Services command, IPMI over lan service was still available.
- Fixed: In the EWS page "Security Settings", when click the "Enable" label of "SSH", "HTTP/HTTPS" and "IPMI over LAN", it will disable or enable the "Force HTTPS" option.
- Fixed: There are assert and de-assert events logged for sensor HDD Status- Device Faulty during DC cycle stress test.
- Fixed: There'll be a warning message for SEL is full after force update BMC
- Fixed: There's no SEL indicate the FW has been updated successfully when update BMC.
- Fixed: The SEL log event ID began at 512 the rather than starting from 1.
- Fixed: SEL log Timestamp message incorrect after AC cycle or BMC reset.
- Fixed: Updated to newer Openssl code version 0.9.8za .

FRUSDR Changes in 1.07:

- Update system Fan1 to FSC domain2, system Fan2 to domain0 in other chassis to align with schematic.




  It is highly recommended to always use the most recent driver version available.