PCI-DB.com
  1. Driver
  2. Motherboard
  3. Intel H2000JF Server System OFU Firmware 02.03.0003/02.01.07.328/01.21.6680/1.12

Intel H2000JF Server System OFU Firmware 02.03.0003/02.01.07.328/01.21.6680/1.12 Download

Posted at December 5, 2024 by PCI-DB Team

Install Driver Automatically
Device NameIntel H2000JF Server System OFU Firmware 02.03.0003/02.01.07.328/01.21.6680/1.12
CategoryMotherboard
ManufacturerIntel
File Size38.6 MB
Supported OSOS Independent

Intel H2000JF Server System OFU Firmware 02.03.0003/02.01.07.328/01.21.6680/1.12 Description

Versions:

- BIOS : 02.03.0003
- ME : 02.01.07.328
- BMC : 01.21.6680
- FRUSDR : 1.12

BIOS 02.03.0003 Changes:

- This version enhances the protection of certain UEFI variables as described in Intel Security Advisory INTEL-SA-00038
- Add "Memory Performance" option in BIOS Setup
- Fixed: IRQ of 10GigE (on board) is not described by BIOS on S4600LH
- Fixed: System does not reset when memory address parity error
- Fixed: Blank console issue fix for McAfee BIOS
- Fixed: CTLE Settings for S4600LH platforms
- Fixed: System halt after creating RAID with 9750 card
- Fixed: User selected power policy not programmed into MSR 0xB01
- Fixed: ME not reporting SmaRT/CLST events to the SEL.
- Fixed: blank lines in server management screen
- Fixed: Change SMBIOS Type 1 - "SKUNum and Family fields" default from "To be filled by O.E.M" to "00"
- Fixed: Show error "BIOS handoff failed"after install Linux OS under UE
- Fixed: The SMBIOS log has wrong description about Port Type in Type 8
- Fixed: Qlogic 4-Port Fiber Channel Cards Configuration does not work
- Fixed: SYSCFG "/bbo" and "/bbosys" not working as expected when "Static Boot Order" Enabled
- Fixed: After setting Admin password to enabled, no password is requested
- Fixed: BIOS needs to support more than 8 NIC boot from PXE
- Fixed: RMS25CB080 -610 board may not be detected on some platforms
- Fixed: IRQ of 10GigE (on board) is not described by BIOS on S4600LH
- Fixed:System does not reset when memory address parity error
- Fixed: CTLE Settings for S4600LH platforms
- Update processor microcode.
- Update support for additional devices on PCIe Gen 3 qualified list on the Intel(R) Server Platforms for E5-4600/2600/2400 CPUs.
- Restore customized defaults when auto recovering from NVRAM corruption
- Update reference code (V02.00.00.03)

ME 2.01.07.328 Changes:

- Fixed: Platform is not able to power on properly after being shut down by NM Policy
- Fixed: Global platform power consumption reported by NM Statistics in S5 is incorrect
- Fixed: OOB (out-of-band) stress test by issuing the wrong username may cause connection to be unavailable
- Fixed: Shutdown action can be interrupted by cold reset when volatile NM policy is in use

BMC 01.21.6680 Changes:

- Fixed: Downgrade RMM4 NIC Link speed from 1G to 100M

FRUSDR 1.12 Changes:

- Upgrade FRUSDR utility to Version 11 Build 20




  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.