Intel R1304WTTGSR Server System OFU Firmware 01.01.0024 Description

Versions:

- BIOS: 01.01.0024
- ME: 03.01.03.043
- BMC: 01.51.11142
- FRUSDR: 1.17

BIOS 01.01.0024 Changes:

- System Boot Timeout function not working if enable Power On Password
- [E5-2600V4]Run chipsec module "python chipsec_main.py -v -m tools.sw_seq" and "python chipsec_main.py -v -m tools.spi_wrsdis" return failed
- [S2600TP] Serial Port should belong internal device not external device in SMBIOS Type8
- FRB watchdog in BIOS does not work when memory initialization failure happens on S2600TP motherboard
- Fixed FIT table 2K alignment issue.
- [E5-2600 v4] SUT will hang up during POST on BIOS R0023 when power on with single QK7S CPU.
- Update E5-2600 v3 ucode to 0000003c, E5-2600 v4 ucode to 0b00002a
- Update the copyright to 2018 

ME 03.01.03.043 Changes:

- Flash from Grantley FW to Grantley-R FW could cause SPS reset.
- System unexpected shutdown with SPS FW exception error.
- ME FW changes P state value when no policy is active impacting performance.
- C8h command power readings for CPU domain are invalid.

BMC 01.51.11142 Changes:

- CPU Throttles all cores to ~50 MHz on S2600BP and S7200AP nodes in chassis with 2130W PSU
- 2130W PSU predictive failure on S2600BP from across customers and across sites

FRUSDR 1.17 FEATURES ADDED

- Modify master.cfg to set the 2U Riser 3 fab 2's FRU and Temp sensor.
- Update new FRUSDR utility ( FRUSDR_V14_0_Build9_AllOS ).

About Firmware Updates:

Applying a newer firmware version than the one already installed on your unit can bring various enhancements, include workarounds for diverse problems encountered by the device, and improve or add newly developed features.

On the other hand, downgrading the firmware version can recover the device's functionality in the event of a software update either turning up faulty or causing the unit's overall performance to drop. However, bear in mind that applying an older firmware isn't recommended and might not always be possible.

When it comes to the update steps, due to the large variety of devices and numerous ways for installing a new firmware, it is recommended that you carefully read and understand the upgrade steps, and consider applying a different firmware only when you have familiarized yourself with the update method.

As the installation process is most of the times quite risky, this step should be taken by users that have the ability to successfully complete the update; regular users may initiate it at their own risk. Moreover, it's best that this task be performed in a steady power environment such as the one ensured by a UPS unit.

Therefore, if you consider applying this release, hit the download button, take into account all the aforementioned aspects, and update the device's firmware. Also make sure you constantly check with our website to ensure that you don't miss a single new release.

  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Intel Drivers

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.