PCI-DB.com
  1. Driver
  2. Motherboard
  3. Intel iMR 3008 ROC Hardware RAID Firmware 24.6.0-0030

Intel iMR 3008 ROC Hardware RAID Firmware 24.6.0-0030 Download

Posted at November 21, 2024 by PCI-DB Team

Install Driver Automatically
Device NameIntel iMR 3008 ROC Hardware RAID Firmware 24.6.0-0030
CategoryMotherboard
ManufacturerIntel
File Size34.8 MB
Supported OSOS Independent

Intel iMR 3008 ROC Hardware RAID Firmware 24.6.0-0030 Description

Versions:

- Firmware Package:24.6.0-0030 (MR 6.5 Point Release)
- Firmware 4.260.01-3883
- ROMENV 1.09
- BootBlock 3.02.00.00-0001
- NVDATA 3.1408.01-0010
- UEFI_Driver 0x06090701 (SIGNED)
- Hii v03.10.09.01(SIGNED)
- FCODE 4.16.08.00
- BIOS 6.20.04.1
- Ctrl-R 5.07-0006
- PCLI 1.07.05

Changes:

- SCGCQ00775267 - (Closed) - 3008 iMR - DPA extended capabilities bits structure is invalid
- SCGCQ00783613 - (Closed) - Firmware logs are not dumped to flash during device discovery phase
- SCGCQ00655162 - (Port_Not_Required) - Failed LED on 10HD BP does not light correctly for a bad drive
- SCGCQ00772911 - (Port_Complete) - Firmware indicating that PD can be spun down even in online state
- SCGCQ00783159 - (Port_Complete) - GPIO 24-31 is should be low when activity is going on drive
- SCGCQ00783186 - (Port_Complete) - Behavior change when FW hit fault code 0x81 (uncorrectable ECC error)
- SCGCQ00788250 - (Port_Complete) - Identify FDE drive compliant to Opal spec and mark them as non-FDE drive
- SCGCQ00775196 - (Port_Complete) - Workaround for Hardware Issue - SCGCQ00632364
- SCGCQ00779356 - (Port_Complete) - Virtual Disk GUID field changes when a VD is moved. The LUID is supposed to be unique and invariant.
- SCGCQ00783180 - (Port_Complete) - The field "expanderFwVersion=" is not populated under "ctrl info" in megamon
- SCGCQ00788252 - (Port_Complete) - Need MR 6.3 iMR Firmware Capable of Updating the SBR on a Customer Board in the Field
- SCGCQ00788283 - (Port_Complete) - Expander reports wrong active firmware version
- SCGCQ00783171 - (Port_Complete) - If diagnostic test fails on the copyback drive the FW does not allow a Recon, Copyback and CC on the same VD.
- SCGCQ00789243 - (Port_Complete) - OEM Expander (Truchas Valley) reporting temperature sensor error
- SCGCQ00762970 - (Port_Complete) - Customer needs NVDATA changes for PHY-to-SLOT mapping
- Various other changes for specific OEMs.
- SCGCQ00759757 - (Closed) - Direction bit is not set for READ CAPACITY commands
- SCGCQ00769319 - (Closed) - The last digit for Expander FW version is truncated
- SCGCQ00769239 - (Closed) - Don't issue REAID I/O on the 4K JBOD

This download is valid for the products listed below:

- Intel RAID Controller RS3WC080
- Intel Integrated RAID Module RMS3HC080
- Intel Server Board S2600CW2
- Intel Server Board S2600CWT
- Intel Server Board S2600CW2S
- Intel Server Board S2600CWTS
- Intel Server Board S2600CWTSR
- Intel Server Board S2600CWTR
- Intel Server Board S2600CW2SR
- Intel Server Board S2600CW2R

About SATA / AHCI / RAID Controllers:

When enabled by appropriate software, the SATA controller (RAID or AHCI) is properly recognized by the system and all of its features are made accessible.

In addition to that, the computer will have the ability to read all adapter characteristics, such as model and manufacturer, and will also be able to manage physical disk drives through the controller’s interface.

If you wish to apply this package, all you have to do is to make sure that the current release is compatible with both your adapter model and your operating system, and then to get the downloadable software. Extract it if necessary, run the available setup, and follow the on-screen instructions for a complete installation.

When finished, remember to perform a system reboot to make sure that all changes take effect properly. Please remember that, even though other OSes might also be compatible, we do not recommend installing this software on platforms other than the specified ones.

That being said, click the download button, get the package and apply it on your computer. Moreover, constantly check with our website to stay up to date with latest releases.

  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Intel Drivers

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.