Device NameIntel ir3 3108 ROC Hardware RAID Firmware 24.3.0-0054
CategoryMotherboard
ManufacturerIntel
File Size34.7 MB
Supported OSOS Independent

Intel ir3 3108 ROC Hardware RAID Firmware 24.3.0-0054 Description

Versions:

- Firmware - 4.230.30-3586
- BIOS - 6.17.04.0
- UEFI_Driver - 0x06060A01 (Signed)
- Hii - 03.07.12.01 (Signed)
- FCODE - 4.16.08.00
- NVDATA - 3.1403.00-0085
- BootBlock - 3.02.00.00-0001
- Ctrl-R - 5.04-0002
- PCLI - 1.07.05
- ROMENV - 1.09

This download is valid for the product(s) listed below

- Intel RAID Controller RS3DC040
- Intel RAID Controller RS3DC080
- Intel RAID Controller RS3MC044
- Intel RAID Controller RS3SC008

Fixes:

- When we attempt to retrieve iMR Thunderbolt controller firmware logs using an application, we see some lines that are wrapped without starting on a new line.
- Serial prints getting jumbled up due to print message inside spurious interrupt handler.
- Data Corruption is taking place on Windows OS installed on top of ESX 5.5 U1 OS.
- ONFI: To properly handle the OCR case with RESET Status Register.
- Cache offload failure with pinned cache on R5 VD
- Defect Fix for VPD and inquiry callback issues in DISM
- Patrol read will not start on any VD after a PR is started, suspended and VD is deleted
- Defect Fix for Command gets retried infinitely times when drive responds with 0B/47/03 always
- FW failure during read on 3PD R5 with 1000 CME with skip count 2
- FW breaks if wrong security key is entered
- Only 1mb crash dump is getting generated of fw fault
- not enough bs found during double Dip power cycle Test
- cache restore failure message displayed through cache restore was successful
- Routines to inject bit error in NF and ecc error in DDR for ONFI
- Mismatch in LD id and target ID during set/reset boot device
- on breaking the multipath in loop while drives are spinning up will result in montask
- FW hangs while creating 64 VDs on the controller with SLES11 SP2
- While running reconstruction from R1 to 4 drive PRL11 with IO,FW hits to MonTask: line 1270 in file ../../raid/1078dm
- SMART poll needs to issue log sense with page control set to current/ cummulative value
- static analysis tool defects resolution
- added support for debug queue
- Not getting "Clear ldbbm badblocks" options on VD
- FW goes to kill adaptor to handle partial copy of crash_dump
- Montask in divert.c seen when injecting 64K consecutive errors on R0 VD, Patrol Read running in background.
- PR Progress event is not generated for 1TB/3TB SATA drive
- Defect fix for kernel panic with iMR Fury with FreeBSD driver
- Running Storcli /C0/CV show or (show all) starts a relearn on supercap issue
- Defect Fix for Online DIF drives are getting punctured after PI enabled R5 VDs are offlined with pinned cache
- md5sum mismatch seen on a copied file from R5 VD with CME
- Power removal of enclosure FW hits to MonTask: line 4056 in file ../../bbu/onfiBBM.c
- Fix GNU make file compilation
- Crash Dump Error Handling
- When OS on VD ,after collecting crash dump file system becomes readable
- Physical drives go to power save mode just after restarting the server
- storcli and CtrlR still show new PD information as 4K sector after replacing a 4K sector drive with a 512 sector drive
- Unexpected power state change
- Media error on Last sector of stripe isn't added to LDBBM list
- CME logic using overlaid fields in c->rec
- defect fix for Compilation issue
- Too many unexpected sense AEN raised by CC during CME recovery on R5
- Not able import foreign configuration immediately after breaking the mirror.
- FW should not try to boot iMR mode without informing host if ECC error happens when OS is running.
- spin up tracker dequeue is not handled for case in which TUR error happens even after MAX retries
- Kill adapter is seen while performing CME recovery during Write operation.
- PDs more than 32 which has configuration, is reporting as JBODs after importing from MR to IMR
- hostCmdSortingWrites is not updated when VD policy changes(WT/WB)
- The restore successful and unsuccessful prints to be handled properly
- code review change implemented
- Changes to support PD IO history
- Enable break mirror support
- Implemented Fix to Problem [PDs more than 32 which has configuration, is reporting as JBODs after importing from MR to IMR]
- Moved divert code from iopath region to save memory
- Update Ptolemy VPD and GasGauge with COL settings for a OEM
- Disable sgpioSmpPresenceDetect for OEM
- Show valid ROC temperature
- Change SES Green/Amber LED behavior
- Extended LDBBM table to hold more bad block entries; with relevant increase in divert nodes.
- Adding test routine for the bad block loop test
- Modify MR fw to eliminate four second window where drive swap is not recognized.
- Single image support for ONFI
- Implement CME solution for "Do not allow 3 minute timer to expire forcing driver to kill fw on CME/disk timeout/etc.
- Make MR to iMR migration generic on TMM fault
- Support for DIS feature in dual image
- command storclif /c1 start diag duration=0 causes controller card to montask.
- BGI operation still running on RAID0 VD even after PI protection disabled
- LED Blink operation doesn't stop after VD deletion
- SGPIO functionality is not working when only cable A is connected
- Potential null pointer dereference
- cache restore failure message displayed through cache restore was successful
- RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset
- CME handling of Invader
- Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap.
- SSD causes system to hang at POST
- Behavior change when FW hit fault code 0x81 (uncorrectable ECC error)
- Adding 2GB DDR and 4GB Flash combination support for Single Image Write.
- FW hits MonTask: line 1143 in file ../../raid/pd.c on starting VD erase in standard mode.
- FW crash while launching Ctrl+R
- 9240-4i is not getting required memory resources on boot, on Linux it waits 5 minutes, resets the
- L2/L3 cache error on H330 MM & H330 MB on reboot
- Work Around for PPC476 Errata number 46 in MR Firmware
- Work Around for PPC476 Errata number 46 in iMR Firmware
- disableBatteryWarning should not be reset if changed by user
- firmware 25.2.0-0013 causes the SEP to not be seen on x4 Equinox
- Transparent Learn Cycle does not kick off and RSOC (Relative State Of Charge) eventually goes down to 0%.
- EEprom CRC error is detected when WebBIOS is running
- AdpDiags does not fail when the SAS link is down
- HDD resume failed during dimmer switch test method.
- Add MaintainPdFailHistory clear function
- Updated long term WA for PPC errata number 46
- For a particular OEM, size of some 4TB drives is reported as zero
- Rebuild failed event is not seen when rebuild fails due to LDBBM and SBBM tables getting full (puncturing disabled)
- Implement I2C Slave Address for Sideband Management
- OEM hi-temp warning not being displayed
- OEM SGPIO support not working
- Retention test failure during stress test
- cntr-R fails to show correct PD sector size once PD's swapped to same slot 512B PD with 512e PD type
- Assertion failure (not enough BS found) in double DIP power cycle test case
- DIS mismatch while running system reboot script with dirty data in DDR
- FW goes to montask at cache offload.
- Megamon during Injecting errors to VD with 512e PDs on iMR controller
- Faulty protocol used for changing the Disk Write Cache Policy
- "OOB:Got DCMD, but FW is not ready " messages are flooding in tty log during OCR .
- Prevent overtemp warnings while charging between 45C and 50C
- adapterOperations.alarmControl is being set to 1 even if controller does not have alarm on board
- CLI Reporting of TMM VPD
- megacli reports battery pack is missing on hot insertion
- MonTask: line 4699 in file ../../raid/ld.c seen on iMR FW during boot to OS with R0 and PRL11 VD
- Do not print VPD86 errors for BP/expander
- Modify WCE bit for improved Linux performance
- When attempting to secure LD during RLM, receive option to secure LD, LD not secured (message incorrect/misleading.)
- Megamon issue when disabling the drive security on a MR controller with spun down FDE drives.
- Unable to open "Set Patrol Read Properties" in MSM with 2008-iMR
- Initialize deviceExposure with MAX_INT13DISKS instead of 0xFF
- Make sure all the make file adheres to the latest binary names.
- Provide an option to limit the max number of INT 13h devices presented to system BIOS
- StartHiiBackEnd() has Print statement with %g
- UEFI Driver should calculate checksum before setting bios data (MR_BIOS_DATA)
- System hang when we press F1 on second time when we are in HII form
- UEFI Driver- has debug print statements during POST
- Diskpart EFI utility can't create partition on a JBOD
- Support EFI_FIRMWARE_MANAGEMENT_PROTOCOL for controller firmware upgrade.
- UEFI Driver returns EFI_NOT_FOUND when platform passes valid Target for ExtSPT.BuildDevicePath()
- Install FMP on Controller Handle at Start() and the exception
- FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304
- User can't access RAID HII in UEFI mode after removing a HDD
- HII\EKM-LKM without reboot should show proper message
- Without selecting any drives I am seeing the previous config VD size.
- Configuration Restore is not working
- StartHiiImpl() WriteToLogger uses %g and EFIHiiDriverEntryPoint() Print statement uses %g for displaying EFI status
- Getting error message when we suspend Patrol read operation through HII browser
- Remove duplicated strings from the UNI FIle
- Allow user to select RAID level when controller has other VD + error handling
- fixing code review defects (AIM version + UCM GUID + deallocation)
- Firmware updation fails in OEM machine
- Form UF003 prints error messages (use WriteToLogger to log these debug messages)
- FWMgmt Prtocol:<config ID="LSIMegaRAIDConfigurationTool"> has no "versionid" info.
- Help content for Firmware Update in Controller Management is inappropriate
- Enter security key for locked drives screen, press down to get to OK, OK will show up again on right
- VD details display is improper in Expand Virtual Drive
- Advanced Controller Properties- Power Saving Settings has broken form
- Able to select EKM even when the EKM FOD key is removed from the system.
- System/HII hang when clicks on Hardware Components menu option in HII.
- On Success of creating Drive Security Form loads into Advanced controller properties
- IMR Liberator Drop Down option in VD properties for Cached is present
- Customize help string for Select Interface Type
- Fill Controller Index in RouteConfig + for UF003 calculate checksum only for the actual config size
- Auto Learn Mode is showing wrong data
- Addressed review comments
- Typo in HII form Controller Status
- Toggling between Legacy to Uefi mode vice versa junk values seen .
- HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key.
- On selecting a wrong parameter for size while creating VDs, Options greyed, Create VD page exits to parent page.
- Security feature is enabled but HII sees "Drive Security" as disabled
- UCM Phase 1: Typo "Clear Configuration" -> "Clear Configuration"
- Handling Code Collaborator Review Defects
- added a while loop and take care of the multiple PD Groups scenario.
- HII should calculate checksum before setting bios data (MR_BIOS_DATA)
- MR6.3 HII aesthetic change
- Changing Percentage of Space to Expand Does not Update Final VD Size
- AIM (Agentless Inventory Manager) Issues
- Creation+ FW updation+ Scan foreign Configuration is disabled/grayed out in HII page
- HII 03.07.05.00/Under advanced controller properties and selecting Cache and Memory, it says's "scontroller cache"
- To address FW Update help Strings
- Not able to schedule CC in concurrent mode from HII(03.07.09.00).
- HII. Provide controller FW update function
- HEFU. Simplify controller property page
- Remove limitation for creating R6 in HII for OEM
- Provide pop-up to display current version and update fw version as part of HEFU HII Firmware Update functionality
- (Implemented) - Create a formset with classGUID that customer has provided.
- Move Disable Protection option from Controller Management to VD management
- System hang observed when the "PdInfo.userDataBlockSize" is set to 0
- HII help for Boot error handling does not display "Stop On Error" option
- Remove FMP installed on the controller handle in HII
- RSOD during POST after enabling SecureBoot - HEFU.ROM should report exact size of .EFI image
- UCM Phase 1: Allow user to select RAID level when controller has other VD + error handling
- Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI
- Missing BBU caused disappearance of Enclosure Mgmt opt in BIOS setup
- HII help window shows unsupported stripe sizes
- In HII on a ready drive we are able to see Used space as 40Gb.
- Enhance help message for PD/VD Operation field
- PCLI(1.07.05) Sparc: Command "cli set securitykey=Lsi@12345" fails with errcd "1001" and errmsg "invalid key".
- Revise Drive Spin-Up Timing on OEM 12G iMR and MR Boards
- Addition of ManPage1 values to the xml file.
- Customer NVDATA Change request for iMR
- Dual write NVDATA changes for customer
- Flatwoods Showing Same Slot Number for All Drives
- breakMirrorRAIDSupport for single span Raid 1
- Memory/battery problems in Focused Regression
- Coherency bit is disabled in SRAM TLBs
- Added a new Control to enable/disable JBOD on the controller in Ctrl Mgmt page.
- Display the Battery status as N/A for iMR cards.
- current write policy is not getting updated until we press f5
- unable to display the reason for difference in write policy
- Both the Connector information(0-3 & 4-7) is not shown in PD properties while connected in Multipath
- Write policy is not added with writeback with BBu when MFC is set
- VD Erase will be disabled in Ctrl+R when Initialization on particular VD is aborted
- Added the code to unset the boot-device to NONE
- StorCLI - MR 6.2 StorCLI help syntax is wrong for R1EC
- PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal".

  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Intel Drivers

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.