NEW FEATURES (ODYSSEY7Q+)

Canon XC10 support:
- UHD Apple ProRes 23.98p, 25p, 29.97p
- UHD->HD SuperSample to Apple ProRes 23.98p, 25p, 29.97p
- (Camera trigger & HDMI timecode in HD Only)

NEW FEATURES (ODYSSEY7Q+ / ODYSSEY7Q)

FS7/FS700 High Speed RAW -> Apple ProRes Support:
- Canon C300 MKII RAW Support
- 4K RAW recording up to 30p
- QHD RAW recording up to 30p
- 4K RAW -> 4K Apple ProRes up to 30p
- QHD RAW -> UHD Apple ProRes up to 30p
- NOTE: Requires Odyssey RAW Bundle or Canon RAW Option

FS7/FS700:
- 4K RAW -> 4K Apple ProRes, 50p & 60p added
- 4K RAW -> UHD Apple ProRes, 50p & 60p added
- 2K RAW HS -> HD Apple ProRes, 100p, 120p, 200p, 240p
- (Only one SSD can be mounted for recording 2K HS Apple ProRes)
- (Only Odyssey int. TC supported (Seed, Time-of-Day DF & NDF)

FS700 only:
- 4K RAW Burst -> 4K Apple ProRes, 100p & 120p
- 4K RAW Burst -> UHD Apple ProRes, 100p & 120p
- NOTE: Requires Odyssey RAW Bundle or Sony FS RAW Option

NEW FEATURES (ODYSSEY7Q+ / ODYSSEY7Q / ODYSSEY7)

Vectorscope:
- Analog or Digital Trace
- Trace display in green or color (true CbCr)
- Variable Zoom 1.0x - 15.0x (Finger Drag left-right)
- Zoom Presets 1,2,5,10,15x (Finger Drag up-down)

FIXES & IMPROVEMENTS:

- FIXED FS700 4K RAW->4K/UHD Apple ProRes issue
- FIXED FS700 2K High Speed->HD Apple ProRes issue
- FIXED FS7 4K RAW->4K/UHD Apple ProRes issue
- FIXED FS7 2K High Speed->HD Apple ProRes issue
- IMPROVED Touchscreen response
- FIXED Audio issues in 1080i59.94 playback
- FIXED 4K to 2K/HD Downscale Line at the bottom of image.
- IMPROVED Color Bars
- IMPROVED Odyssey Menu Font
- FIXED 4K / UHD ProRes HQ/ LT/ 422 Bit Rate issue
- FIXED FS700 4K Raw to 4K / UHD ProRes File Audio Sync Issue
- FIXED FS7 4K Raw to 4K / UHD ProRes File Audio Sync Issue

KNOWN ISSUES:

- 2K Raw 23.98-60p is not supported in 2K Raw HS to HD ProRes.
- On Canon XC10 camera trigger and HDMI timecode are not supported in UHD but work in HD.
- Canon XC10 camera trigger and HDMI timecode are not supported in UHD but work in HD.
- FS7/700 2K RAW HS->HD Apple ProRes only supports 100p-240p. For 2K or HD 23.98-60p derived from RAW, use 4K RAW->2K/HD Apple ProRes modes.
- ALEXA SUP 11.0.1 contains metadata changes and is not supported. For ARRIRAW recording, SUP 11.0 is recommend for all ALEXA users.
- LUTs are not currently supported in Multi-Stream mode.
- Occasionally in Canon RAW -> Apple ProRes, playback audio may be out of sync. Switch to LIVE, then back to PLAY for proper sync. Recorded files are uneffected.
- Occasionally in Canon RAW, playback audio may be out of sync. Recorded files are unaffected.

KNOWN ISSUES From 2015.8.1074

Monitor:
- 4K HDMI input, HDMI output has lines in the image. Note SDI output is unaffected. Recording is unaffected.
- Color Bars on, powering up unit with video source connected can result in a black screen. Disconnect SDI or HDMI to remedy.
- Some Preset LUTs may need to have Extended/Legal ranges adjusted when selected.
- Image Analysis Tool Overlays are slower than previous firmware (Lines on the display).
- Graticules for Image Analysis Tools are not currently displayed on the video outputs.
- Anamorphic Desqueeze is not supported in Canon Half Raw at this time.
- When PSF output is selected OLED display is interlaced.
- Occasionally the touch screen will seem less responsive, to remedy this, press the F1 button, to initiate the screen lock and recalibrate the OLED display. Note it may take several times of performing this to return normal functionality.

Play:
- Playback of Sony 4K RAW (on Odyssey7Q+ only) occasionally shifts image slightly horizontal. Recording is unaffected.
- Playback C500 Raw 50/59.94, maybe playback, or shifted, to remedy, select live, then play and play clip again. Recording is Unaffected.

Record:
- Remove 3:2 Pulldown is not supported in DPX.
- Remove 3:2 pulldown with Canon C100.
- Occasionally when viewing or recording 4K/UHD->2K/HD SuperSample, lines can appear on the OLED display. Recorded files as unaffected.
- IN FS700 4K Raw Burst mode (100p/120p), ten extra frames are recorded at the end of each clip. Occasionally these are bad frames. This will be corrected in future firmware from 450 frames to proper 440 frames.
- IN FS700 4K Raw Burst mode (100p/120p) -> 2K/HD Apple ProRes, the amount of frames that are recorded may vary based on trigger type and clip to clip. Note the Odyssey always records 420+ frames in this mode.
- FS7/ FS700 Audio Sync issue with 4K Raw to 4k / UHD ProRes.
- False Start with FS700 4K Raw to ProRes using Camera Trigger when switching frame rates. (results in a 2 second clip)
- FS7 / FS700 2K Raw High Speed ProRes ->Occasionally there are block artifacts that are recorded on several frames.
- 4K / UHD ProRes HQ/ LT/ 422 Bit Rate issue from HDMI or SDI source.

Operation:
- SSD Detection is longer than previous 5-10 seconds.
- Loading of SSD LUTS can take up to 30 seconds.
- Occasionally LUT deletion does not work correctly. Deleted LUTs may reappear after power cycle. Resetting LUTs in *->ODYSSEY->RESET menu will delete all imported LUTs.

KNOWN ISSUES From 2015.7:

Monitor:
- 4K HDMI input, HDMI output has lines in the image. Note SDI output is unaffected. Recording is unaffected.
- Color Bars on, powering up unit with video source connected can result in a black screen. Disconnect SDI or HDMI to remedy.
- Some Preset LUTs may need to have Extended/Legal ranges adjusted when selected.
- Image Analysis Tool Overlays are slower than previous firmware (Lines on the display).
- Graticules for Image Analysis Tools are not currently displayed on the video outputs.
- Anamorphic Desqueeze is not supported in Canon Half Raw at this time.
- When PSF output is selected OLED display is interlaced.
- Occasionally the touch screen will seem less responsive, to remedy this, press the F1 button, to initiate the screen lock and recalibrate the OLED display. Note it may take several times of performing this to return normal functionality.

Play:
- Playback of Sony 4K RAW (on Odyssey7Q+ only) occasionally shifts image slightly horizontal. Recording is unaffected.

Record:
- Remove 3:2 Pulldown is not supported in DPX.
- Remove 3:2 pulldown with Canon C100.
- Occasionally when viewing or recording 4K/UHD->2K/HD SuperSample, lines can appear on the OLED display. Recorded files as unaffected.
- IN FS700 4K Raw Burst mode (100p/120p), ten extra frames are recorded at the end of each clip. Occasionally these are bad frames. This will be corrected in future firmware from 450 frames to proper 440 frames.
- IN FS700 4K Raw Burst mode (100p/120p) -> 2K/HD Apple ProRes, the amount of frames that are recorded may vary based on trigger type and clip to clip. Note the Odyssey always records 420+ frames in this mode.
- FS7/ FS700 Audio Sync issue with 4K Raw to 4k / UHD ProRes.
- False Start with FS700 4K Raw to ProRes using Camera Trigger when switching frame rates. (results in a 2 second clip)
- FS7 / FS700 2K Raw High Speed ProRes ->Occasionally there are block artifacts that are recorded on several frames.
- 4K / UHD ProRes HQ/ LT/ 422 Bit Rate issue from HDMI or SDI source.

Operation:
- SSD Detection is longer than previous 5-10 seconds.
- Loading of SSD LUTS can take up to 30 seconds.
- Occasionally LUT deletion does not work correctly. Deleted LUTs may reappear after power cycle. Resetting LUTs in *->ODYSSEY->RESET menu will delete all imported LUTs.

PREVIOUS KNOWN ISSUES:

Audio:
- SDI/HDMI outputs occasionally will not carry audio. Cycle Odyssey power to restore.
- SDI/HDMI audio occasionally will have a static pop when powering up.
- Audio will occasionally swap tracks when recording in DPX.
- Using Analog Audio and HDMI video, occasionally SDI, HDMI and headphone outputs do not carry audio.
- Audio output (headphones) occasionally flips channels.

Monitor:
- Focus Assist in Edge Enhanced mode and recording Apple ProRes 422(HQ) shows edges as white instead of selected color.
- PIXEL ZOOM in RAW or DPX occasionally causes stretching of image.
- Recording is unaffected.
- Switching between ARRIRAW 1.5G DL and 3G DL occasionally can make the image incorrect on the OLED screen. Disconnect & reconnect one of the SDI inputs to correct. Recording is unaffected.
- SDI/HDMI outputs have a pink line in image on Canon C500 2K 12-bit/10-bit video. Recording is unaffected.
- IO Industries RAW files do not send color balance metadata to the Odyssey7Q so images appear incorrect.
- Recorded metadata color balance is set to 5600K but is not baked in.

Play:
- PLAY mode audio occasionally out of sync.
- Playlist occasionally reports timecode as “00:00:00;00”. Eject and re-insert
- the SSD to correct.
- FS700 RAW files occasionally show vertical line on right edge of frame.
- Recording is unaffected.
- FS700 RAW 60p files occasionally play with jitter. De-select and
- re-select to correct. Recording is unaffected.
- Multiple clip playback not supported in RAW formats.
- Canon UHD RAW occasionally plays back black image. De-select and re-select to correct. Recording is unaffected.

Record:
- ARRIRAW 4:3 mode is currently unsupported.

Post:
- FS RAW files appear green when imported directly into SpeedGrade. This is corrected in Speedgrade 2015. Pending Adobe update, import via dynamic link from Premier.
- Canon Cinema 4K half RAW 100/120 does not work in Adobe or Resolve

Working with Adobe and BMD to resolve:
- In Resolve 11 Lite, FS7 and FS700 RAW (CinemaDNG) files may appear underexposed

IMPORTANT NOTES:

- Updating firmware on an Odyssey monitor/recorder requires the use of an SSD.
- If an Odyssey monitor/recorder is currently running firmware version 5.10.100 (March 2015) or 2015.5 (May 2015) then a qualified Samsung SSD (see list above) as well as an Odyssey SSD can be used to perform the update.
- Samsung SSDs require the Convergent Design SSD Handle kit to mount in an Odyssey monitor/recorder.
- Odyssey monitor/recorders running earlier firmware versions must use an Odyssey SSD to perform the update.

About Digital Camera Updates:

Updating to a newer firmware version than the one already installed on your camera can improve the device’s overall performance and stability, resolve various issues, and add support for newly developed features or enhance existing ones.

On the other hand, downgrading the camera’s firmware can recover its functionality in the unlikely event the currently installed version is faulty or the device’s performance dropped after an upgrade. However, bear in mind that applying an earlier build might not always be possible.

It is recommended that changing the camera’s firmware be performed when the new release resolves an issue that your device has been encountering, or adds a new feature (or enhances an existing one) that could prove useful for you.

This process isn’t intended to be destructive, but still, it’s best to save all your personal data and configurations before applying a different firmware. Moreover, make sure that the battery is fully charged and don’t use the camera’s buttons while the installation is in progress.

When it comes to the update method, usually, you must copy the firmware file onto a compatible memory card, insert it into the camera, and browse from the menu to the device’s update section.

However, each device has various ways to enter the update mode and particular steps that should be taken for a successful upgrade, therefore make sure you read the product’s installation guide.

That being said, if you consider that this firmware improves your device in any way, then hit the download button and get the desired version; if not, check with our website as often as possible so that you don’t miss the update that will boost your camera’s performance. 

  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related OTHERS Drivers

AOC 2275W LCD Monitor Driver 1.0.0.0 for Windows 10

Device Type: Monitor File Size: 30 KB Windows 10 ,Windows 10 64 bit

Install Driver

AOC 2275W LCD Monitor Driver 1.0.0.0

Device Type: Monitor File Size: 30 KB Windows 7 ,Windows 7 64 bit ,Windows 8 ,Windows 8 64 bit ,Windows 8.1 ,Windows 8.1 64 bit

Install Driver

Lenovo E2415p LCD Monitor Driver 1.0.0.0

Device Type: Monitor File Size: 30 KB Windows 7 ,Windows 7 64 bit ,Windows 8 ,Windows 8 64 bit ,Windows 8.1 ,Windows 8.1 64 bit

Install Driver

Lenovo E2415p LCD Monitor Driver 1.0.0.0 for Windows 10

Device Type: Monitor File Size: 30 KB Windows 10 ,Windows 10 64 bit

Install Driver

HAMA Black Force USB Gamepad Driver 1.0

Device Type: Joystick Gamepad Wheels And Tablets File Size: 1.6 MB Windows XP ,Windows Vista ,Windows XP 64 bit ,Windows Vista 64 bit ,Windows 7 ,Windows 7 64 bit

Install Driver

Lenovo ThinkPad E455 Monitor Driver 5.06

Device Type: Monitor File Size: 306 KB Windows 7 ,Windows 7 64 bit ,Windows 8 64 bit ,Windows 8.1 64 bit ,Windows 10 64 bit

Install Driver

Crystalfontz LCD Module USB Driver 20150304

Device Type: Monitor File Size: 9.4 MB Windows XP ,Windows Vista ,Windows 2008 ,Windows Vista 64 bit ,Windows 7 ,Windows 7 64 bit

Install Driver

Crystalfontz CFA835 LCD Module USB Driver 1.0.0.0

Device Type: Monitor File Size: 8.4 MB Windows 7 ,Windows 7 64 bit ,Windows 8 ,Windows 8 64 bit ,Windows 8.1 ,Windows 8.1 64 bit

Install Driver

HP Compaq L2105tm Wide LCD Monitor Driver

Device Type: Monitor File Size: 375 KB Windows All

Install Driver

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.