PCI-DB.com
  1. Driver
  2. Firmware
  3. Intel R2000LH2 Server System Family Firmware 2.03/2.01/1.21/0.23

Intel R2000LH2 Server System Family Firmware 2.03/2.01/1.21/0.23 Download

Posted at November 23, 2024 by PCI-DB Team

Install Driver Automatically
Device NameIntel R2000LH2 Server System Family Firmware 2.03/2.01/1.21/0.23
CategoryFirmware
ManufacturerIntel
File Size39 MB
Supported OSOS Independent

Intel R2000LH2 Server System Family Firmware 2.03/2.01/1.21/0.23 Description

Versions:

- BIOS: R02.03.0003
- ME: 02.01.07.328
- BMC: 01.21.6038
- FRUSDR: 0.23

BIOS R02.03.0003

- This version enhances the protection of certain UEFI variables as described in Intel Security Advisory INTEL-SA-00038

BMC changes in release 01.21.6038

- Fixed: BMC User configuration is corrupted and users cannot be re-created.
- Fixed: The response of getting satellite fw update status is always 01
- Fixed: HSC slots status present sensor showed NA in EWS.
- Fixed: (X) Disk Drive LED - Locating drive is inconsistent in time to illuminate and stop
- Fixed: Hot Plug Fan not changing system status on Fan failure.
- Fixed: EWC Fan sensor readings disappear when filtered and there is a fan failure.
- Fixed: (X) BMC hung after network Scan.
- Fixed: Current power is incorrect on EWS while power down SUT by pressing power button.
- Fixed: Special characters '<>' of FRU info can't be shown in the EWS page.
- Fixed: Recurring temperature alarms on sensor #0x22(SSB).
- Fixed: DIMM Thrm Mrgn sensor shows "unknown" when just plug DIMM in Channel3
- Fixed: [X] Updated Java signitures to support new JAVA requirements.
- Fixed: Get SOL Configuration parameters 5 & 6 should not return invalid response.
- Fixed: EWS is incorrectly decoding ME firmware update SEL events.
- Fixed: BMC channle 1 can not ping succesfully and EWS login fail while using static IPV6 address.
- Fixed: Baseboard IP address can't be assigned when IPv6 address set as auto-configuration.
- Fixed: IP address can't be assigned when IPv6 address set as dynamic.
- Fixed: BMC Hangs during first A/C power up.
- Fixed: CFM calculation failed on PSU removal/insertion.
- Fixed: Enable FPGA logic to preserve PWM registers.
- Fixed: Check in 750AB V8 PSU image per PSU verification team's request
- Fixed: Porting FRU discovery APIs from Grantley where the Auto-Configuration feature requires the operational status of the managed FRUs.
- Fixed: Add the displaying of the PS HW Revison for the PS if update is required or not.

ME changes in release 02.01.07.328

- Fixed: Platform is not able to power on properly after being shut down by NM Policy.
- Fixed: Global platform power consumption reported by NM Statistics in S5 is incorrect.
- Fixed: OOB (out-of-band) stress test by issuing the wrong username may cause connection to be unavailable.
- Fixed: Shutdown action can be interrupted by cold reset when volatile NM policy is in use.

FRUSDR changes in release 0.23

- Changed LC/LNC thresholds for all CPUs to match processor specs.




  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Intel Drivers

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.