Posted at November 21, 2024 by PCI-DB Team
Install Driver AutomaticallyDevice Name | Intel R2000GZ Server System IDA/OFU Firmware 2.03.0003 |
---|---|
Category | Motherboard |
Manufacturer | Intel |
File Size | 36.8 MB |
Supported OS | OS Independent |
- BIOS: 02.03.0003
- ME: 02.01.07.328
- BMC: 01.21.6038
- FRUSDR: 1.13
- This version enhances the protection of certain UEFI variables as described in Intel Security Advisory INTEL-SA-00038
- Add "Memory Performance" option in BIOS Setup
- Fixed: IRQ of 10GigE (on board) is not described by BIOS on S4600LH
- Fixed: System does not reset when memory address parity error
- Fixed: Blank console issue fix for McAfee BIOS
- Fixed: CTLE Settings for S4600LH platforms
- Fixed: System halt after creating RAID with 9750 card
- Fixed: User selected power policy not programmed into MSR 0xB01
- Fixed: ME not reporting SmaRT/CLST events to the SEL.
- Fixed: blank lines in server management screen
- Fixed: Change SMBIOS Type 1 - "SKUNum and Family fields" default from "To be filled by O.E.M" to "00"
- Fixed: Show error "BIOS hand off failed"after install Linux OS under UE
- Fixed: The SMBIOS log has wrong description about Port Type in Type8
- Fixed: Qlogic 4-Port Fiber Channel Cards Configuration does not work
- Fixed: SYSCFG "/bbo" and "/bbosys" not working as expected when "Static Boot Order" Enabled
- Fixed: After setting Admin password to enabled, no password is requested
- Fixed: BIOS needs to support more than 8 NIC boot from PXE
- Fixed: RMS25CB080 -610 board may not be detected on some platforms
- Fixed: IRQ of 10GigE (on board) is not described by BIOS on S4600LH
- Fixed:System does not reset when memory address parity error
- Fixed: CTLE Settings for S4600LH platforms
- Update processor microcode.
- Update support for additional devices on PCIe Gen 3 qualified list on the Intel Server Platforms for E5-4600/2600/2400 CPUs.
- Restore customized defaults when auto recovering from NVRAM corruption
- Update reference code (V02.00.00.03)
- Fixed: Platform is not able to power on properly after being shut down by NM Policy
- Fixed: Global platform power consumption reported by NM Statistics in S5 is incorrect
- Fixed: OOB (out-of-band) stress test by issuing the wrong username may cause connection to be unavailable
- Fixed: Shutdown action can be interrupted by cold reset when volatile NM policy is in use
- Fixed: BMC User configuration is corrupted and users cannot be re-created.
- Fixed: The response of getting satellite fw update status is always 01
- Fixed: HSC slots status present sensor showed NA in EWS.
- Fixed: (X) Disk Drive LED - Locating drive is inconsistent in time to illuminate and stop
- Fixed: Hot Plug Fan not changing system status on Fan failure.
- Fixed: EWC Fan sensor readings disappear when filtered and there is a fan failure.
- Fixed: (X) BMC hung after network Scan.
- Fixed: Current power is incorrect on EWS while power down SUT by pressing power button.
- Fixed: Special characters '<>' of FRU info can't be shown in the EWS page.
- Fixed: Recurring temperature alarms on sensor #0x22(SSB).
- Fixed: (X) S600GL/S2600GR - Fail EMC Brownout testing.
- Fixed: DIMM Thrm Mrgn sensor shows "unknown" when just plug DIMM in Channel3
- Fixed: [X] Updated Java signatures to support new JAVA requirements.
- Fixed: Get SOL Configuration parameters 5 & 6 should not return invalid response.
- Fixed: EWS is incorrectly decoding ME firmware update SEL events.
- Fixed: BMC channel 1 can not ping successfully and EWS login fail while using static IPV6 address.
- Fixed: Baseboard IP address can't be assigned when IPv6 address set as auto-configuration.
- Fixed: IP address can't be assigned when IPv6 address set as dynamic.
- Fixed: BMC Hangs during first A/C power up.
- Fixed: Reading the PCI Riser temperature sensors for S2600CP was not operating correctly.
- Fixed: CFM calculation failed on PSU removal/insertion.
- Fixed: Enable FPGA logic to preserve PWM registers.
- Fixed: Check in 750AB V8 PSU image per PSU verification team's request
- Fixed: Porting FRU discovery APIs from Grantley where the Auto-Configuration feature requires the operational status of the managed FRUs.
- Fixed: Add the displaying of the PS HW Revision for the PS if update is required or not.
It is highly recommended to always use the most recent driver version available.
Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.
Device Type: Graphics Board File Size: 300 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 300 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 111.5 MB Windows 8
Install DriverDevice Type: Graphics Board File Size: 148.1 MB Windows 8.1 64 bit
Install DriverDevice Type: Graphics Board File Size: 355.1 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 117 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 49.8 MB Windows 7 64 bit
Install DriverDevice Type: Graphics Board File Size: 25.3 MB Windows 7 64 bit
Install DriverDevice Type: Graphics Board File Size: 355.1 MB Windows 10 64 bit
Install DriverDevice Type: Graphics Board File Size: 354.1 MB Windows 10 64 bit
Install DriverFind Missing Drivers
Recent Devices
Recent Drivers
© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.