PCI-DB.com
  1. Driver
  2. Motherboard
  3. Intel ir3 2208 ROC Hardware RAID Firmware 23.28.0-0010

Intel ir3 2208 ROC Hardware RAID Firmware 23.28.0-0010 Download

Posted at April 29, 2024 by PCI-DB Team

Install Driver Automatically
Device NameIntel ir3 2208 ROC Hardware RAID Firmware 23.28.0-0010
CategoryMotherboard
ManufacturerIntel
File Size11.7 MB
Supported OSOS Independent

Intel ir3 2208 ROC Hardware RAID Firmware 23.28.0-0010 Description

Firmware- 3.400.05-3175

- External Key management security for iMR
- Not seeing the correct Boot Message when the connection to the External Key Management server is down
- Re-keying a controller with External Key Management(EKM) security enabled, results in a corrupted key ID.
- Performing an online firmware update or Online Controller Reset(OCR) on a controller with External Key Management(EKM) enabled, results in all secured drives marked as foreign.
- Raid configuration loss after reboot- PDs in POWERSAVE
- Re-keying in External Key Management mode followed by disabling security and enabling LKM results in a bail out while creating a Virtual Drive
- FW debugger scrolls continuous message and eventually resets after deleting Source VD during a Cachecade disassocation
- Switching to Local Key Management Mode(LKM) after a rekey in External Key Management(EKM) rekey without rebooting results in HII saying key incorrect but Firmware says key was created.
- On a controller with Local Key Management(LKM) enabled, user is asked to enter the security key to unlock and import a foreign, locked and External Key Management(EKM) enabled drive.
- After starting Patrol Read in the HII application, booting to OS and checking the status in MSM shows Patrol Read as suspended.
- Getting Question Value mismatch when entering Controller management screen
- MR to iMR downgrade error
- Pinned cache gets flushed to incorrect VD for mirrored RAID levels
- Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap.
- Cannot create pinned cache during an Online Controller Reset (OCR)
- Switching the security mode from External Key Management(EKM) to Local Key Management(LKM) on iMR controller will result in a corrupted controller key.
- Getting a non informative message when trying to import a Virtual Drive after a re-key without reboot
- Internal Development team defect to check-in gemini image to resolve SSD drives missing issue.
- Unable to suspend the Patrol Read operation in iMR mode from the HII application
- Bad battery warning message that comes up during POST isn't aligned properly.
- HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM
- Firmware break into montask, when there is a pinned cache( During bootup and OCR )
- Controller breaks into montask if you have 10 enclosures connected to the controller.
- VD erase does not resume and complete after reboot.
- A data TLB error occurs when the External Key Management Server(EKMS) is down and drive security is changed from External Key Management(EKM) mode to Local Key Management(LKM) mode.
- Remove redundant code within a particular function
- Storecli reporting incorrect values for tfm and supercap date of manufacture
- Static analysis tool defects
- Unable to discard pinned cache in Headless Safe Mode.
- Enhance code to catch Stack Overflow problem as soon as it occurs.
- Write buffer flash programming support
- Implement I2C Slave Address for Sideband Management
- Add Fastpath Support by Default for a particular OEM.
- When pinned cache present VD property not changing from WB to WT.
- PDs go online without VD created & App doesn't allow any VD creation on passing a wrong parameter in Spanned VD.
- Booting a 12G server into a degraded Raid 5 array will result in limited functionality
- Improve Boot time that was lengthened due to previous change.
- (DDR3) CKE and Reset clamping circuit can cause DDR errors at initialization time
- Incorrect variable type in MR Read/Modify/Write path
- Gemini image updated
- Raid configuration loss after reboot- PDs in POWERSAVE
- RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset
- OEM MR TB controller reports foreign configuration on adapter during a 100 AC power cycles
- Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap.
- FW sending wrong configuration data during boot msg pending state
- I/O's fail and VD becomes failed during planned failover of owner node w/ SMB I/O
- Configuration import of GHS (Global Host spare) fails.
- Firmware hits Montask when drive is pulled after changing the volume property from read ahead to no read .
- VPD output of lspci –vvxxx showing [RV] Reserved: checksum bad, 86 byte(s) reserved
- Gemini image updated
- disableBatteryWarning should not be reset if changed by user
- An invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive
- Fix for Infinite retries of command for sense code 0B/47/03
- Liberator Card loses its boot VD after many reboots
- Upgrading from Software RAID to 9260-8i causes Alarm to sound
- Incorrect variable type in MR Read/Modify/Write path
- Bad or Missing TMM boot message is changed to Critical error
- In case of a certain OEM iMR shows R5 enabled.
- Running out of free entries in task list due to recursive addition of tasks
- Fix for Infinite retries of command for sense code 0B/47/03
- RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset
- Kill adapter is seen while performing CME recovery during Write operation.
- CME logic using overlaid fields in c->rec
- system black screen during S1 Sleep test
- Operating System event log reports a controller error during stress testing
- With Headless Continue On Error Mode(HCOE) enabled and the SafeStore BIOS password enabled, if the wrong password is entered you are stuck at the same screen .
- An invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive
- Liberator Card loses its boot VD after many reboots
- Code Review: Call DDF_discardInvalidPds only if DS3 is enabled
- FW take a long time to boot to OS
- Cluster validation failed in disk arbitration
- HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM
- Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95%.
- Patrolread will not start on any VD after a PR is started, suspended and VD is deleted
- VD goes offline when we start reconstruction on 32 Drive R0 VD
- Clear up stale cache lines.
- OEM MR TB controller reports foreign configuration on adapter during a 100 AC power cycles
- MR 6.3: md5sum mismatch seen on a copied file from R5 VD with CME
- Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95%.
- search for one wire devices prints are masked after the boot

BIOS- 5.46.02.0

- Initialize deviceExposure with MAX_INT13DISKS instead of 0xFF
- Make sure all the make file adheres to the latest binary names.
- Provide an option to limit the max number of INT 13h devices presented to system BIOS

Hii- 03.07.11.00

- HII\EKM-LKM without reboot should show proper message
- With out selecting any drives I am seeing the previous config VD size.
- Confiuration Restore is not working
- StartHiiImpl() WriteToLogger uses %g and EFIHiiDriverEntryPoint() Print statement uses %g for displaying EFI status
- Getting error message when we suspend Patrol read operation through HII browser
- Remove duplicated strings from the UNI FIle
- Allow user to select RAID level when controller has other VD + error handling
- fixing code review defects (AIM version + UCM GUID + deallocation)
- Firmware updation fails
- Form UF003 prints error messages (use WriteToLogger to log these debug messages)
- FWMgmt Prtocol:<config ID="LSIMegaRAIDConfigurationTool"> has no "versionid" info.
- Help content for Firmware Update in Controller Management is inappropriate
- Enter security key for locked drives screen, press down to get to OK, OK will show up again on right
- VD details display is improper in Expand Virtual Drive
- Advanced Controller Properties- Power Saving Settings has broken form
- Able to select EKM even when the EKM FOD key is removed from the system.
- System/HII hang when clicks on Hardware Components menu option in HII.
- On Success of creating Drive Security Form loads into Advanced controller properties
- Drop Down option in VD properties for Cached is present
- Customize help string for Select Interface Type
- ill Controller Index in RouteConfig + for UF003 calculate checksume only for the actual config size
- Auto Learn Mode is showing wrong data
- Addressed review comments
- Typo in HII form Controller Status
- Toggling bewtween Legacy to Uefi mode vice versa junk values seen .
- HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key.
- n selecting a wrong parameter for size while creating VDs, Options greyed, Create VD page exits to parent page.
- Security feature is enabled but HII sees "Drive Security" as disabled
- Typo "Clear Configuaration"-> "Clear Configuration"
- added a while loop and take care of the multiple PD Groups scenario.
- HII should calculate checksum before setting bios data
- MR6.3 HII aesthetic change
- Changing Percentage of Space to Expand Does not Update Final VD Size
- AIM (Agentless Inventory Manager) Issues
- Creation+ FW updation+ Scan foreign Configuration is disabled/grayed out in HII page
- Under advanced controller properties and selecting Cache and Memory, it says's "scontroller cache"
- To address FW Update help Strings
- Not able to schedule CC in concurrent mode from HII(03.07.09.00).
- HII. Provide controller FW update function
- HEFU. Simplify controller propety page
- Remove limitation for creating R6 in HII
- Provide pop-up to display current version and update fw version as part of HEFU HII Firmware Update functionality
- Create a formset with classGUID that customer has provided.
- Move Disable Protection option from Controller Management to VD management
- Able to select EKM even when the EKM FOD key is removed from the system.
- System hang observed when the "PdInfo.userDataBlockSize" is set to 0
- HII help for Boot error handling does not display "Stop On Error" option
- HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key.
- Enter security key for locked drives screen, press down to get to OK, OK will show up again on right
- HII\EKM-LKM without reboot should show proper message
- UCM Phase 1: Allow user to select RAID level when controller has other VD + error handling
- System hang observed when the "PdInfo.userDataBlockSize" is set to 0
- HII help window shows unsupported stripe sizes
- Missing BBU caused disappearance of Enclosure Mgmt opt in BIOS setup
- In HII on a ready drive we are able to see Used space as 40Gb.
- Typo "Clear Configuaration"-> "Clear Configuration"
- added a while loop and take care of the multiple PD Groups scenario.

FCODE- 4.16.08.00

UEFI_Driver- 0x06060900
- UEFI Driver: StartHiiBackEnd() has Print statement with %g
- UEFI Driver should calculate checksum before setting bios data
- System hang when we press F1 on second time when we are in HII form
- UEFI Driver- has debug print statements during POST
- Diskpart EFI utility can't create partition on a JBOD
- Support EFI_FIRMWARE_MANAGEMENT_PROTOCOL for controller firmware
- UEFI Driver should calculate checksum before setting bios data
- UEFI Driver returns EFI_NOT_FOUND when platform passes valid
- User can't access RAID HII in UEFI mode after removing a HDD

WebBIOS- 6.1-71-e_71-Rel

NVDATA- 2.1403.03-0128
- Added support for subOEM 8 version of Alcor-S 9271 Controller

PCLI- 05.07.00

BootBlock- 2.05.00.00-0010

BootBlockCommon- 07.26.26.219

ROMENV- 1.08

This download is valid for the products listed below:

- Intel Integrated RAID Module RMS25CB040
- Intel Integrated RAID Module RMS25CB080
- Intel Integrated RAID Module RMS25PB040
- Intel Integrated RAID Module RMS25PB080
- Intel Integrated RAID Module RMT3CB080
- Intel Integrated RAID Module RMT3PB080
- Intel RAID Controller RS25AB080
- Intel RAID Controller RS25DB080
- Intel RAID Controller RS25NB008
- Intel RAID Controller RS25SB008

  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Intel Drivers

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.