PCI-DB.com
  1. Driver
  2. Motherboard
  3. Intel iMR 3008 ROC Hardware RAID Firmware 24.18.0-0021

Intel iMR 3008 ROC Hardware RAID Firmware 24.18.0-0021 Download

Posted at December 21, 2024 by PCI-DB Team

Install Driver Automatically
Device NameIntel iMR 3008 ROC Hardware RAID Firmware 24.18.0-0021
CategoryMotherboard
ManufacturerIntel
File Size48.2 MB
Supported OSOS Independent

Intel iMR 3008 ROC Hardware RAID Firmware 24.18.0-0021 Description

Firmware Package: 24.18.0-0021 (MR 6.13)

- Firmware 4.670.00.6501
- ROMENV 1.09
- BootBlock 3.07.00.00-0003
- NVDATA 3.16011.01-0001
- UEFI_Driver 0x06160200(signed)
- Hii 03.23.06.00(signed)
- FCODE 4.19.08.00
- BIOS 6.34.01.0
- Ctrl-R v5.18-0400
- PCLI 1.07.05

Bug Fixes and Enhancements:

- SCGCQ01111615 - (Closed) - Changing RAID FoD key(Add/Remove) through customer application will make original VD to foreign
- SCGCQ01111966 - (Closed) - LSA displays discrepant information for empty backplanes
- SCGCQ01116419 - (Closed) - With controller operating in least latency mode, FW hits montask upon running IOs
- SCGCQ01117839 - (Closed) - MRFW : Exception in Core 0 while importing Foreign Config with enclosure connections swapped.
- SCGCQ01126892 - (Closed) - On performing DIF R6 rebuild operation result in DIF errors
- SCGCQ01130036 - (Closed) - PR fails to continue on PD after a USER paused Patrol read is resumed after OCR.
- SCGCQ01136710 - (Closed) - To fix compilation issue in 6.13
- SCGCQ01139294 - (Closed) - CTRL-H allowing user to enable protection .
- SCGCQ01144627 - (Closed) - FW hits to montask with mutipath push/pull operation
- SCGCQ01150161 - (Closed) - Don't allow SESVPDAssociationTypeInMultiPathCfg to change for OEM THOR via controller property
- SCGCQ01151384 - (Closed) - Build the Flash Component List only if any of the image is flashed.
- SCGCQ01152599 - (Closed) - Assertion failure in ../../dm/mpt2/mptcmd.c at line 1418 during PD offline on R5 using DIF drives.
- SCGCQ01154299 - (Closed) - Dev defect: kill adapter debugging information are missing in the crash dump collection path.
- SCGCQ01161841 - (Closed) - IMR FW fails to support 32 configured good drives, during JBOD to good and array removal step.
- SCGCQ01162896 - (Closed) - In case of Raid 6 and medium error on the drives, if the driver state is manually changed to OFFLINE, FW hits a DMA error
- SCGCQ01167011 - (Closed) - FW crashes while running a power cycle test.
- SCGCQ01169202 - (Closed) - MR_6.13 : Issuing Hibernation during rebuild with IO result to Assertion failure
- SCGCQ01177023 - (Closed) - Default behavior is not set to JBOD during personality switch from EPD to JBOD
- SCGCQ01177948 - (Closed) - MR_6.13_FW: Kill Adapter on running multipath push pull
- SCGCQ01180459 - (Closed) - VD with 4Kn drives, performance is slow with 6.10/6.11. Issue not seen on 6.9
- SCGCQ01187677 - (Closed) - Update the macro name as appropriate
- SCGCQ01191412 - (Closed) - HDD LED issues
- SCGCQ01192863 - (Closed) - MR 6.13 Alpha OEL 7.2:MonTask: line 538 in file ../../dm/mpt2/mptcmd.c while running multipath cable breaker script
- SCGCQ01193231 - (Closed) - Linux,eSDS-MR6.12 Replan RC: -6% to -15% Perf drop in all IO size with Higher QD in 12G SAS HDD [x16EC,x24EC,x40EC]
- SCGCQ01196132 - (Closed) - cachecade feature is enabled through FOD key,is not entertained unless reboot/reset the controlller
- SCGCQ01208120 - (Closed) - Foreign config import boundary conditions
- SCGCQ01208490 - (Closed) - 2G DDR Write Timeouts with Medusa DM discovery issue
- SCGCQ01213918 - (Closed) - 6.13-Beta: MonTask: line 3386 in file ../../dm/src/devmgr.c while running JBOD IO on SAS SSD with cable pull push
- SCGCQ01225116 - (Closed) - MRIntru6.13RC-Win/Lin:~38% drops SW 4/8/16/32/64/128K QD(1-256) R0/R5/R6/R10 40D/24DEC/16DC 12G-SASHDD/6G-SATAHDD/12G SAS SSD
- SCGCQ01226439 - (Closed) - FW crash with more than 64 VD's while performing RAID->JBOD/JBOD->RAID switch
- SCGCQ01128576 - (Closed) - 6.13_SDS: Handling the SYNC_CACHE command for WB EPDs
- SCGCQ01132432 - (Closed) - Security is disabled on a MR controller after a FOD key is added or removed until next reboot.
- SCGCQ01135815 - (Closed) - FW fails to import DIF arrays, after changing enable PI controller property 0 -> 1
- SCGCQ01149312 - (Closed) - Dev defect: number of messages in the VDM queue is not initialized with proper values
- SCGCQ01155893 - (Closed) - Dev defect: To check-in 3316 specific params page update changes.
- SCGCQ01163849 - (Closed) - IMR_6.13: Drive is not marked as Foreign upon OCR when controller already has max configured PD's
- SCGCQ01167814 - (Closed) - For hidden VDs incorrect VD access Policy shown in the LSA
- SCGCQ01201595 - (Closed) - FW crashes during SSC VD import on a system having certain VDs
- SCGCQ01208167 - (Closed) - Windows MR6.13 Alpha-eSDS 3108:-7 to -13% Perf Drops SR IO Sizes-4K,8K,16K QD(8) SATA SSD x8,x16,x24 PD,EPD (Coalescing)
- SCGCQ01208304 - (Closed) - Read timeouts observed during Cache Restore on 4gig boards.
- SCGCQ01117827 - (Closed) - MRFW : OCR disabled while fw downgrade from 6.12 to 6.4
- SCGCQ01137690 - (Closed) - Controller exports 1 MB as IO size irrespective of its type/mode.
- SCGCQ01172369 - (Closed) - FW is observing Kill Adapter while CCVD disassociate in progress
- SCGCQ01188556 - (Closed) - Coverity defects CID 15746, 18327 and 18574
- SCGCQ01191216 - (Closed) - FW crashes when LDs were deleted during rebuild operation.
- SCGCQ01199711 - (Closed) - FW crashes upon firing storcli show all command
- SCGCQ01204471 - (Closed) - Termlog is not persistent across boots when tty hist is ON.
- SCGCQ01208906 - (Closed) - Aborted Erase is resumed after OCR in SDS & RAID mode .
- SCGCQ01156908 - (Closed) - MR_6.13_FW:PD not displayed by StorCLI, does not allow to change state of the PD as well.
- SCGCQ01163865 - (Closed) - MR FW returning invalid return code while setting link speed.
- SCGCQ01180987 - (Closed) - MR 6.13 PA3:DATA TLB Error MonTask: line 245 in file ../../raid/1078int.c after disabling multipath bit and OCR
- SCGCQ01187690 - (Closed) - Coverity tool issue: Code indention and Unintentional integer overflow issues
- SCGCQ01117190 - (Closed) - MR_6.13_FW: Kill Adapter on running multipath push pull
- SCGCQ01170701 - (Closed) - Configuration lost and system crashed on having a stale configuration connected
- SCGCQ01188437 - (Closed) - Fix for coverity defects CD: 17745 and CD: 18227
- SCGCQ01190895 - (Closed) - RDM in Use-RDm Error & crashed into Montask during boot (SCGCQ01147739 DU issue)
- SCGCQ01185882 - (Closed) - Coverity Issues
- SCGCQ01185858 - (Closed) - Coverity : Array Out-of-bounds access error reported
- SCGCQ01190905 - (Closed) - MRIntrud6.13Alpha-Win/Lin Upto ~30% drops are observed SW for 4k/8K/16k/32K/64K/128K QD(1-256) for R0/R5/R10 for 12G SAS HDD.
- SCGCQ01196090 - (Closed) - Copy-Back resumes from Zero after foreign import with reboot.
- SCGCQ00853162 - (Closed) - MPI 2.5: Update Description of BiosOptions field in BIOS CONFIG PAGE 1
- SCGCQ01226974 - (Implemented) - Check in PL version 13.00.03.00
- SCGCQ01216305 - (Implemented) - MR6.13: Disable SDS personality mode
- SCGCQ01187730 - (Closed) - Integrating PL(SCGCQ01183279) 13.00.01.00 in 3108 6.13
- SCGCQ01170212 - (Closed) - Autoconfig feature support for 64 VD mode.
- SCGCQ01156969 - (Closed) - Firmware does not turn fault LED for drives with size < 512MB
- SCGCQ01155304 - (Closed) - The security key lifecycle management for EKMS
- SCGCQ01150052 - (Closed) - Change DDR Tuning Settings in Response to ECC errors
- SCGCQ01141427 - (Closed) - Enable SDS personality mode
- SCGCQ01139341 - (Closed) - WG: Instance Validation issues pertaining to Energy pack (GET).
- SCGCQ01134167 - (Closed) - Need MCTP over PCIe enabled for SMC 3108 design - unblock current MCTP/PCIe level
- SCGCQ01134165 - (Closed) - Adding the function that changing flag of full initialize completion
- SCGCQ01085797 - (Implemented) - User can save the FoD key to TMM through the MSM pop-up advanced software options.
- SCGCQ01156825 - (Closed) - Integrating PL(SCGCQ01140801) 13.00.00.00 to 6.13 3316
- SCGCQ01082117 - (Closed) - Change DDR Tuning Settings in Response to ECC errors
- SCGCQ01213219 - (Closed) - Integrating PL SCGCQ01210438 (13.00.02.00) into 3316 6.13 .
- SCGCQ01210265 - (Closed) - Integrating PL (SCGCQ01208895) to 6.13 3108
- SCGCQ01199671 - (Closed) - MegaRAID 3108 ROMB with 2GB DDR3 for cachevault single write mode (FW Change)
- SCGCQ01156111 - (Closed) - Integrating PL(SCGCQ01140806) 13.00.00.00 to MR 6.13
- SCGCQ01129378 - (Closed) - SCSI SANITIZE/Crypto on JBOD Drives under MR
- SCGCQ01181178 - (Implemented) - Investigate on unalligned IO's for 512E drives with background operation
- SCGCQ00829979 - (Port_Complete) - FW upgrade from non 240VD FW to 240VD FW when OS is behind the controller results in BSOD
- SCGCQ00829980 - (Port_Complete) - FW upgrade from non 240VD FW to 240VD FW when OS is behind the controller results in BSOD
- SCGCQ00988970 - (Port_Complete) - PDs are getting swapped and starts rebuild on wrong VD after the enclosure power cycle
- SCGCQ01033483 - (Port_Complete) - Exception handler table is always addressed to primary FW region in iMR controller.
- SCGCQ01082876 - (Port_Complete) - Upgraded to MR5.14, still see "I2C 4 PID 10 SCL STUCK Low! while I2C Rx receiving data intStatus 00008000" in fw log.
- SCGCQ01130999 - (Port_Complete) - I/O failures observed on 4kn VD with data Protection Enabled
- SCGCQ01131001 - (Port_Complete) - I/O failures observed on 4kn VD with data Protection Enabled
- SCGCQ01132984 - (Port_Complete) - Improve performance of of Cachecade associated SVDs for 512K 100% RW FIO Workload
- SCGCQ01133565 - (Port_Complete) - FDE Error messages were seen due to incorrect handling of sense data
- SCGCQ01134074 - (Port_Complete) - Request for FW to disable all PI, and not allow to be re-enabled
- SCGCQ01136062 - (Port_Complete) - Data Miscompare found during recovery of CacheCade pinned windows across OCR/Reboot or discard of CacheCade pinned windows while CacheCade degrade flush in progress
- SCGCQ01136063 - (Port_Complete) - Data Miscompare found during recovery of CacheCade pinned windows across OCR/Reboot or discard of CacheCade pinned windows while CacheCade degrade flush in progress
- SCGCQ01139844 - (Port_Complete) - FW crashes when setting fwtermlog bbu=on to a card with bad NAND flash
- SCGCQ01140902 - (Port_Complete) - Security is disabled on a MR controller after a FOD key is added or removed until next reboot.
- SCGCQ01141456 - (Port_Complete) - CTRL-H allowing user to enable protection .
- SCGCQ01145325 - (Port_Complete) - Need MCTP over PCIe enabled for OEM 3108 design - unblock current MCTP/PCIe level
- SCGCQ01146497 - (Port_Complete) - EPD's are not created when pd erase is in progresss on one/more of the drive s after system reboot
- SCGCQ01149762 - (Port_Complete) - iMR: Drives with configuration is getting converted to JBOD if system already has maximum configurable drives.
- SCGCQ01149763 - (Port_Complete) - iMR: Drives with configuration is getting converted to JBOD if system already has maximum configurable drives.
- SCGCQ01150028 - (Port_Complete) - Dev defect: number of messages in the VDM queue is not initialized with proper values
- SCGCQ01150067 - (Port_Complete) - FW:Add capability to expose each SAS Expander-attached SEP as a separate Enclosure PD
- SCGCQ01150173 - (Port_Complete) - Request for NVdata change on 9361-8i to make the minimum stripe size 16K (instead of 64K)
- SCGCQ01152709 - (Port_Complete) - FW crashes when setting fwtermlog bbu=on to a card with bad NAND flash
- SCGCQ01155380 - (Port_Complete) - SCSI SANITIZE/Crypto on JBOD Drives under MR
- SCGCQ01155454 - (Port_Complete) - L2/L3 Cache error was detected on the RAID controller during boot (24 hours after shutdown hang)
- SCGCQ01158838 - (Port_Complete) - iEEESGL flag was not getting set for IO request in SES DCDB handler
- SCGCQ01163258 - (Port_Complete) - LUID gets changed during foreing import from non-240VD FW to 240VD FW
- SCGCQ01174094 - (Port_Complete) - Fake the progress response to application until background operation resumes
- SCGCQ01174409 - (Port_Complete) - Enhance code to catch Stack Overflow problem as soon as it occurs.
- SCGCQ01175616 - (Active) - New Erase Type CRYPTO ERASE is supported for ISE capable drives via DCMDs.
- SCGCQ01180170 - (Port_Complete) - Controller exports 1 MB as IO size irrespective of its type/mode.
- SCGCQ01180872 - (Port_Complete) - Function in FW (injectParityErr) doesn't work to generate i-cache parity error
- SCGCQ01184957 - (Port_Complete) - xIOV_Step2.5 : BladeErrorIsrTask while running IO's.
- SCGCQ01201996 - (Port_Complete) - MR7.0 - DC when a PD is made offline during RLM of single Dr. R0 to 4 Dr. R1 (PRL11)
- SCGCQ01202625 - (Port_Complete) - Assertion failure in ../../raid/cache.c at line 2495: during RHEL 7.1 OS boot after VDs are created
- SCGCQ01205307 - (Port_Complete) - Rebuild does not start when "useunconfiggoodforemergency" feature is enabled and one "prepare for removal" drive is undone.
- SCGCQ01205341 - (Port_Complete) - CSCuy34722: Memory size and CacheVault Flash size show wierd values
- SCGCQ01205429 - (Port_Complete) - iEEESGL flag was not getting set for IO request in SES DCDB handler
- SCGCQ01206978 - (Port_Complete) - FW trying ld sync for target ID beyond 63 when non-240 driver is installed
- SCGCQ01063833 - (Port_Complete) - DC Reboot Caused an LTO Drive Attached to H330 Controller to Load a Tape.
- SCGCQ01131000 - (Port_Complete) - I/O failures observed on 4kn VD with data Protection Enabled
- SCGCQ01131002 - (Port_Complete) - I/O failures observed on 4kn VD with data Protection Enabled
- SCGCQ01149114 - (Port_Complete) - Kill-adapter during rebuild, recon, and drive pull
- SCGCQ01170646 - (Port_Complete) - Local storage admin config FSM failure on setting TR on 64 VDs
- SCGCQ01180171 - (Active) - Controller exports 1 MB as IO size irrespective of its type/mode.
- SCGCQ01180864 - (Port_Complete) - For SES enclosures, now we call a wrapper function to get the correct slot number before setting the bad slot bitmap.
- SCGCQ01184451 - (Port_Complete) - Copyback not automatically initiating when manually setting drives to Unconfigured_Good
- SCGCQ01202208 - (Port_Complete) - IMR_6.13: Drive is not marked as Foreign upon OCR when controller already has max configured PD's
- SCGCQ01205340 - (Active) - 32MB Image doesn't boot on PP boards
- SCGCQ01205397 - (Port_Complete) - Configuration lost and system crashed on having a stale configuration connected
- SCGCQ01163768 - (Port_Complete) - LUID gets changed during foreing import from non-240VD FW to 240VD FW
- SCGCQ01131003 - (Port_Complete) - I/O failures observed on 4kn VD with data Protection Enabled
- SCGCQ01141508 - (Port_Complete) - xIOV:PL Fault 0000d073/0000d101 for shutting down the host during IO in SDS,1660 in file ../../dm/pl2/pliopi.c
- SCGCQ01176519 - (Port_Complete) - xIOV:PL Fault 0000d073 for running IO on shared EPDs across hots with Heavy load.
- SCGCQ01203802 - (Port_Complete) - MR7.0 - DC when a PD is made offline during RLM of single Dr. R0 to 4 Dr. R1 (PRL11)
- SCGCQ01014121 - (Port_Complete) - LSI Controller in configuration lost state
- SCGCQ01158573 - (Port_Complete) - Request not to reset the Idle Timers.
- SCGCQ01185730 - (Closed) - With controller in JBOD mode try to create VDs R1 and R0 from CTRL_H the FW breaks with Data TLB error.
- SCGCQ01033486 - (Closed) - Adpinfo doesn't show detail Pending Flash FW info via storcli
- SCGCQ01064480 - (Closed) - MFI Frame alignment
- SCGCQ01155309 - (Closed) - Storcli SegFault -HUU update utility doesn't detect SBMezz if Foreign Config PD exist
- SCGCQ01184721 - (Resolved) Displays Errorcode 255 for controller information (c0 show)
- SCGCQ01185690 - (Closed) - Removed Missing return values in Libmods
- SCGCQ01193194 - (Closed) - storcli crashes while trying to load configuration
- SCGCQ01196471 - (Closed) - Regardless of Drive availability, Ctrl-R Create vd gave an option to create array.
- SCGCQ01185184 - (Closed) - Removing the logically dead code from CLI.
- SCGCQ01185673 - (Closed) - Removing the logically dead code from Libmods
- SCGCQ01136658 - (Closed) - CTRL-H: Add new checkbox [Use existing security Key ] in Change security key
- SCGCQ01093152 - (Closed) - Correcting error messages for transport errors.
- SCGCQ01109142 - (Closed) - Storcli /c0 show all is not displaying OS driver version.
- SCGCQ01112673 - (Closed) - Storcli needs to be fixed for maximum TR info in ctrl show all
- SCGCQ01138814 - (Closed) - CTRL-H- Add warning message before we change the behavior mode and it's parameters
- SCGCQ00942269 - (Closed) - LibMod Ctrl-R is allowing to enable and disable JBOD on the controller in SDS Mode
- SCGCQ01146002 - (Closed) - Ctrl-H: Overlap of config parameters in JBOD behavior mode
- SCGCQ01079824 - (Closed) - eSDS_1.1_HSW_Beta: Storcli after Saving and Restoring configuration using file doesn't list EPD and JBOD in PDlist type
- SCGCQ01139839 - (Closed) - Avago HBA : Ctrl-R doesnt prompt for hot spare drive selection while creating Vd
- SCGCQ01194348 - (Closed) - Create Virtual Drive" enabled after reaching max config
- SCGCQ01136661 - (Closed) - CTRLH- Add error Handling for prepare for removal and undo prepare for removal
- SCGCQ01185187 - (Closed) - CTRL-H:handle coverity defects
- SCGCQ01141462 - (Closed) - LibMods : Adding the function that changing flag of full initialize completion
- SCGCQ01112370 - (Implemented) - Contains Libmods changes for FRU implementation (CLI ER: SCGCQ01097099 )
- SCGCQ00907898 - (Implemented) - LibMod:Add ISA and MR Personality Mode Support
- SCGCQ00950485 - (Closed) - Do not allow VD creation on Removal Ready PD
- SCGCQ01134132 - (Implemented) - Add support for new version OpenSSL1.02g to support "DROWN" - CVE-2016-0800
- SCGCQ00879989 - (Implemented) - LibMod Changes: Add ISA and MR Personality Mode Support
- SCGCQ01145285 - (Implemented) - Ctrl-H - LibMods: Rename HBA mode to JBOD mode
- SCGCQ01030217 - (Port_Complete) - storcli64 Emulated Physical Drive section shows incorrect capacity for 2TB 4k HDDs
- SCGCQ01139832 - (Port_Complete) - SED-Ctrl-R-Security/Confirm Key is being displayed in plain text format
- SCGCQ00995143 - (Port_Complete) - Connector name is not in sorted state when queried from storcli .
- SCGCQ01046049 - (Port_Complete) - -Memory coruption message with SWR, with "eall show" command
- SCGCQ01176928 - (Port_Complete) - Updated the string from "Instant Secure Erase" to "Cryptographic Erase"
- SCGCQ00928044 - (Port_Complete) - Inconsistency in showing controller status between MSM and StorCLI for Fake Flash errors
- SCGCQ00928097 - (Port_Complete) - LibMod: Display connector and Enclosure information for backplane drives
- SCGCQ01141291 - (Port_Complete) - Avago HBA : Ctrl-R doesnt prompt for hot spare drive selection while creating Vd
- SCGCQ01146026 - (Port_Complete) - Ctrl-H: Overlap of config parameters in JBOD behavior mode
- SCGCQ00928099 - (Port_Complete) - Checking-in Libmod changes for defect-SCGCQ00914834
- SCGCQ01123359 - (Port_Complete) - CLI Checkin for PPC Little Endian Compilation.
- SCGCQ01144779 - (Port_Complete) - Libmod changes: Adding CLI command to display/toggle new controller property.(SCGCQ01106982)
- SCGCQ01146785 - (Port_Complete) - Added the code to display the JBOD personality and switch between the JBOD and RAID personalities
- SCGCQ00928098 - (Port_Complete) - LibMods: Add support to enable/Disable of Large IO Support - 1 MB IO
- SCGCQ00939845 - (Port_Complete) - Buffer is not incremented when reading sector of the drive
- SCGCQ00942788 - (Port_Complete) - eSDS Alpha : LibMod Ctrl-R is allowing to enable and disable JBOD on the controller in SDS Mode
- SCGCQ01146028 - (Port_Complete) - Ctrl-H - LibMods: Rename HBA mode to JBOD mode
- SCGCQ01146783 - (Port_Complete) - FW crashes when setting fwtermlog bbu=on to a card with bad NAND flash
- SCGCQ01201335 - (Port_Complete) - sparc version storcli tool can not execute storcli /cx show for 3316 card
- SCGCQ01200478 - (Port_Complete) - Check hostMemRequired bit at appropriate place in INT15Trapper()
- SCGCQ01134128 - (Closed) - The security key lifecycle management for EKMS
- SCGCQ01191839 - (Port_Complete) - RSOD encountered on reboot system
- SCGCQ01205305 - (Port_Complete) - EFI driver test Red-screen-of-death
- SCGCQ01193228 - (Closed) - HII provides an option Full initialization for R60 DIF array during array creation
- SCGCQ01164506 - (Closed) - MR6.12 HII : Title for select drive form is shown as HF030 when creating vd in raid mode
- SCGCQ01143300 - (Closed) - Fix HII issues related to EKMA
- SCGCQ00883008 - (Closed) - Profile Mgmt API Changes
- SCGCQ00886417 - (Closed) - MR_RAID_CTX_G35 has one too many bits
- SCGCQ00927738 - (Closed) - Reintroduce numSGEExt Field in Raid Context for 3108 to support 1MB IO
- SCGCQ00948535 - (Closed) - The code had events with repetitive ID and some structures clashing
- SCGCQ01001936 - (Closed) - CtrlInfo.adapterOperations3.supportProfileChange is missing in 3516 Dev API baseline dated 2015-12-23
- SCGCQ01014835 - (Closed) - CtrlInfo.adapterOperations3.supportProfileChange is missing in 3516 Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4
- SCGCQ01196215 - (Closed) - ASSERT text seen on screen when entering system menu
- SCGCQ01138815 - (Closed) - HII- Add warning message before we change the behavior mode and it's parameters
- SCGCQ01164510 - (Closed) - Form title for convert JBOD s to UG when creating a vd is shown as HF041 on the confirmation page .
- SCGCQ01122925 - (Closed) - Error Displayed which HII Dashboard form is launched
- SCGCQ01214389 - (Closed) - "Check all" does not select drives during creation of VD
- SCGCQ01195985 - (Closed) - Create SSC VD option displayed when max VDs are configured
- SCGCQ01156878 - (Closed) - Switching Personality is not showing in HII
- SCGCQ01145633 - (Closed) - HII exits when attempted preview foreign configuration while the drives are pulled out
- SCGCQ01176614 - (Closed) - UCM 2.0 is not fully supported by controller
- SCGCQ01167163 - (Closed) - HII:handle coverity defects
- SCGCQ01208732 - (Closed) - Junk value seen in JBOD to UG conversion form
- SCGCQ01146597 - (Closed) - MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY
- SCGCQ01141251 - (Closed) - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES
- SCGCQ01139344 - (Closed) - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters
- SCGCQ01137627 - (Closed) - MR 6.13: Add a new control command to fetch ROC temperature data over I2C
- SCGCQ00867953 - (Closed) - profile management API
- SCGCQ00875328 - (Closed) - Mega API modifications needed for RMW-FP and Cache bypass features in 3516
- SCGCQ00883262 - (Closed) - Merging api_overrides mega_api files with the files in the Mega_API development stream
- SCGCQ01023741 - (Closed) - MR_CTRL_INFO expansion from 2K to 4K
- SCGCQ01059740 - (Closed) - mega api changes for ibuttonless PR
- SCGCQ01075821 - (Closed) - Profile Management Changes to support requestedProfileID and optimisedProfile
- SCGCQ01094549 - (Closed) - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO
- SCGCQ01133839 - (Closed) - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file
- SCGCQ01144381 - (Implemented) - HII to support UCM 2.0 for 3108 (9361-8i) based controllers
- SCGCQ01134128 - (Closed) - The security key lifecycle management for EKMS
- SCGCQ01145284 - (Closed) - HII: Rename HBA mode to JBOD mode
- SCGCQ01140914 - (Port_Complete) - "Autoconfigure Raid 0" option is available in HII even in absence of ready HDDs
- SCGCQ01140915 - (Port_Complete) - PRL-11 VD expansion fails
- SCGCQ01166472 - (Port_Complete) - Form title for convert JBOD s to UG when creating a vd is shown as HF041 on the confirmation page .
- SCGCQ01204956 - (Port_Not_Required) - Import Foreign Config menu option is shown in HII when in HBA mode
- SCGCQ01204962 - (Port_Complete) - Battery Temperature is listed as High in Battery Management menu in HII when temp is 29C/84F.
- SCGCQ01140917 - (Port_Complete) - HII Profile VD performs a BGI after created, but displays a Default Initialization of Full or Fast at time of creation
- SCGCQ01204964 - (Port_Complete) - HII - Unable to change task rates with "+/-"
- SCGCQ01205277 - (Port_Not_Required) - HII - "Check All" does NOT select all drives when creating VD
- SCGCQ01169018 - (Port_Complete) - With large VDs creating from Free Space will fail on first attempt
- SCGCQ01205298 - (Port_Complete) - 9460-16i - Unable to migrate RAID6 to RAID5
- SCGCQ01206747 - (Port_Complete) - PKG 214/HII giving a Question Value Mismatch trying to add another VD using free space from a degraded VD.
- SCGCQ01191839 - (Port_Complete) - RSOD encountered on reboot system
- SCGCQ01205299 - (Port_Complete) - HII requires for user to enter security key three times to disable/enable pass pharse at the boot time.
- SCGCQ01140910 - (Port_Complete) - Incorrect drop down menu of VDs while initiating RLM for the second time in HII.
- SCGCQ01140911 - (Port_Complete) - With no ready disk, no. of Eligible NonRaid pds to convert to ready state shows zero
- SCGCQ01180959 - (Port_Complete) - Dont allow user to set 4K JBOD as a boot device from PD management
- SCGCQ01205305 - (Port_Complete) - EFI driver test Red-screen-of-death
- SCGCQ01146029 - (Port_Complete) - HII: Rename HBA mode to JBOD mode
- SCGCQ01166525 - (Port_Complete) - MR6.12 HII : Title for select drive form is shown as HF030 when creating vd in raid mode
- SCGCQ01167058 - (Port_Complete) - HII- VD creation fails with available free capacity in single disk group
- SCGCQ01204953 - (Port_Complete) - HII exits when attempted preview foreign configuration while the drives are pulled out
- Miscellaneous changes for different OEMs.

UEFI (EFI 2.0) instructions for updating RAID Firmware:

1. Download and extract all files to a local drive.
2. Boot the target system to EFI shell.
3. Change directory to the local drive and directory containing the flash update files and the firmware image file.
4. Type "update.nsh" or "eficmdtool2 -adpfwflash -f MR514p3.rom -noverchk -aall"
5. Wait for the flash to complete. Do NOT reboot the system during the update.

Windows and Linux instructions for updating RAID Firmware:

- The firmware update may be run from Within Windows or Linux using the appropriate versions of CmdTool2.
-In Windows, unzip the utility into the same directory as the rom file by typing "cmdtool2 -adpfwflash -f MR514p3.rom -aall".
-The Linux CmdTool2 by running the rpm and then calling the utility from /opt/MegaRAID/CmdTool2 as "./CmdTool2 -AdpFwFlash -f MR514p3.rom -aall"

DOS instructions for updating RAID Firmware:

1. Download and extract all files to a local drive.
2. Boot the target system to DOS.
3. Change directory to the local drive and directory containing the flash update files and the firmware image file.
4. Type "update.bat" or "doscmdtool2 -adpfwflash -f MR514p3.rom -aall"
5. Wait for the flash to complete. Do NOT reboot the system during the update.

This download is valid for the products listed below:

- Intel Compute Module HNS2600TP24R
- Intel Compute Module HNS2600TPFR
- Intel Server Board S2600TP
- Intel Compute Module HNS2600TPF
- Intel Server Board S2600CWTSR
- Intel Compute Module HNS2600KP24R
- Intel Server Board S2600TPFR
- Intel RAID Controller RS3WC080
- Intel Server Board S2600KPTR
- Intel Integrated RAID Module RMS3HC080
- Intel Server Board S2600TPF
- Intel Compute Module HNS2600TP
- Intel Compute Module HNS2600TP24S
- Intel Compute Module HNS2600TP24SR
- Intel Compute Module HNS2600TP24STR
- Intel Server Board S2600KPR
- Intel Server Board S2600CW2SR
- Intel Server Board S2600KPF
- Intel Compute Module HNS2600TPR
- Intel Server Board S2600KPT
- Intel Server Board S2600KP
- Intel Compute Module HNS2600KP
- Intel Server Board S2600KPFR
- Intel Compute Module HNS2600KPFR
- Intel Compute Module HNS2600KPF
- Intel Compute Module HNS2600KPR
- Intel Server Board S2600TPR
- Intel Compute Module HNS2600KP24
- Intel Compute Module HNS2600TP24

About SATA / AHCI / RAID Drivers:

When you install an operating system, SATA settings (be it AHCI, RAID, or IDE mode) are detected from the BIOS. If you want to change from one mode to another after the OS has been applied, appropriate drivers are required.

Bear in mind that if you modify these settings without installing proper files first, the operating system will not be able to boot until changes are reverted or required drivers are applied.

To perform the latter task, get the package, run the available setup and follow the instructions displayed on-screen for a complete installation. Afterwards, perform a system reboot so that all changes take effect, enter BIOS menu, and set the SATA option to the mode that best describes the newly applied drivers.

So, if you intend to modify the SATA settings to the mode described by this release, click the download button, and make the desired changes. In addition to that, don't forget to constantly check with our website so that you don't miss a single new release.

  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Intel Drivers

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.