PCI-DB.com
  1. Driver
  2. Firmware
  3. Intel ir3 2208 ROC Hardware RAID Firmware 23.18.0-0013

Intel ir3 2208 ROC Hardware RAID Firmware 23.18.0-0013 Download

Posted at April 28, 2024 by PCI-DB Team

Install Driver Automatically
Device NameIntel ir3 2208 ROC Hardware RAID Firmware 23.18.0-0013
CategoryFirmware
ManufacturerIriver
File Size14.5 MB
Supported OSOS Independent

Intel ir3 2208 ROC Hardware RAID Firmware 23.18.0-0013 Description

Versions:

- MR Firmware – 3.290.05-2720
- Ctrl-R – 4.02-0001
- BootBlock – 2.05.00.00-0010
- BootBlockCommon – 07.26.13.219
- ROMENV – 1.08

Fixes:

- Virtual Drive creation failure in iMR during pre-boot
- Recon VD made "degraded" when the recon pd is pulled out allowing for rebuild once the drive is plugged back in.
- Static variable used in PD Progress and LD Progress function which may affect multiple progresses running at the same time.
- MegaRAID controller does not display a boot message when it has entered safe mode.
- Allow adding a lba when table entries are exhausted, but addition is possible if consecutive to existing entry
- When pulling and pushing SSD SATA PDs under 5 seconds, the SSDs come back as failed after a minute or so.
- Hard coded values should be removed in TFM module
- Potential IO integrity with R0/R1 CIO WT when overlapping R/W issued to LD.
- Unable to perform Consistency Check and other background operations in a legacy WebBIOS
- Multiple VDs undergoing full init show a calculated estimated time remaining even though they sit at 0%
- FW reports "Progress init not proper" during 16 VD Rebuild
- Data miscompare seen when errors injected to a RAID6 virtual drive
- Potential data integrity issue During Check Consistency On 4DG R6 arrays with 16 VDs per array
- Delete VD while PR still in progress cause debugger to loop. Reboot the system, debugger still loops
- Sequential Read performance is less on CacheCade associated LD's.
- If a BOOT Passphrase is enabled with SafeStor "MegaCli adpbios dsply a0" will display "BIOS will Stop on error" even if any other mode is set.
- Message release issue in immediate IO path
- Firmware crash during foreign config import
- Verify drive reinsertion within/before drive-removal-delay setting -verify discovery (Without IO)
- HII - Profile based VD creation - [Partial RAID options blocked until system reboot]
- Application could not make a JBOD bootable without a VD present
- Potential data integrity issue with a 4K RAID5 virtual drive
- HII /When user has a critical message and the conrtoller is in Safe Mode, going into CTRL mang will result an error msg
- Staggered CMEs across R10 array are causing a read error
- Learn cycle will not start on supercap
- UEFI-4K drives: Unable to create any virtual drives of strip size 256k-1MB with the 4K sector drives.
- Event is blocked during Full initialization
- iMR firmware does not progress background operations with certain systems when using WebBIOS in legacy mode
- Fw defects related to Disk Write Cache Policy settings
- Grammatical spacing error in bios message at POST
- The elapsed time shown in the FW debugger for a reconstruction not starting at 0
- 23.16.0.0005/Creating CacheCade with non supported OEM SSD using older FW and then flashing to 5.7 it's till available
- "Question value mismatch with Option Value" message in HII's Controller Management when in Safe Mode with pin cache
- Rebuild failed event is not seen when rebuild fails due to LDBBM and SBBM tables getting full (puncturing disabled)
- Remove memory module on MR controller to downgrade to iMR does not work
- Firmware failed to import drives to start rebuild after remove then reinsert
- LDBBM_EXT table does not get read during init
- Significant drop in Sequenial read performance with Read Ahead policy
- Multi-stripe size in each raid level of R1,r5,r6 with SAS, DIF, 4K pinned cache offline vd import cause Montask
- Setting the ASO key with storcli 1.02.08 (MegaCli 8.07.06) fails with an error code 3 on Windows or Linux if the MB BIOS PCI
- Data Miscompare found while running I/O overnight with degraded virtual drives
- HII critical message form/Extra character "r" with configuration not supported critical message.
- Prevent overtemp warnings while battery is charging
- CLI Reporting of TMM VPD
- EKMS disabled in firmware by modifying support EKM property in a proper way.
- Modify MR fw to eliminate four second window where drive swap is not recognized.
- Rebuild automatically starts on drive with foreign configuration after reboot.
- Modify sense data returned for an offline VD
- Availability of information on PFK hardware keys presence/absence via termlog.
- HA/Peer controller detection and handling logic
- R5 rebuild fails source drive after LDBBM table is full
- Defect fix for crash when fde disk connected
- Ctrl+R BIOS hangs while hot plug of 2 enclosures with more than 32 drives on FURY controller
- Sequential Read performance is less on CacheCade associated LD's.
- The reliability and error recovery of the SuperCap firmware was improved.
- Adjusted the USB phy boost value for the OEM controllers
- IO integrity error seen after Source VD associated with CacheCade VD is forcibly unblocked
- During rebuild on PRL11 CacheCade VD and rebuild on RAID6 Source VD IO integrity error is seen.
- BBU Charging gets disabled when Transparent Relearn fails to start due to low capacity
- On iMR FW update caused card to FW fault state and card cannot boot to OS.
- SEAGATE hotspare drives remain spun up on LSI FW 12.12.0-0079
- After COR (OCR) controller not longer available to HOST
- Change SES Green/Amber LED behavior for OEM JBOD enclosure.
- Customer is hitting an ECC bug
- Firmware returns invalid data in OOB packet
- OEM facing with incorrect SAS HDD's indication, MSM shows 2X drives connected
- Alarm continues to sound after copy-back is done, across reboot, from an unconfigured good drive that is used as an emergency spare.
- Change RAID controller FW bad battery warning message that comes up during POST.
- 2208 ROMB see 0 Capacitance
- Deep learn doesn't start when it is requested during relaxing.
- Auto Foreign import fails when controller is booted with pinned cache.
- Power loop cycle test on a non DIF drive connected to LSI controller caused fatal firmware error
- When a Cachecade PD marked as missing is reused to make Cachecade VD IO integrity error is observed.
- If a correctable ECC error occurred during a cache offload, the CPU would crash, resulting in a data loss
- Copy back on a drive hits kill adapter
- Immediate IO broken for R1
- disableHII: Needs to be updated from nvdata into MFCD
- Infinite retry happens on Test Unit command when HDD didn't respond to TU command during the initialization.
- Enable DS3 on TB code for OEM
- TFM error handling : Cache policy change for WB to WT if supercap is faulty
- OEM- StorCli should not allow turning on JBOD in MR mode
- Deep Learn is not invoked in new battery, when the system is reboot before the first learn completes
- Transparent Learn Cycle is rescheduled even though it is not completed
- Write policy changed from WT to WB when the battery/Supercap is declared as bad
- OCR observed after IO on reconstructed VD with ME's
- Wrong event generated "Reminder: Potential non-optimal configuration due to drive PD xx(e0xfc/sx) commissioned..
- If the hotspare was spun down, the copy back after a drive failure wouldn't always start.
- adapterOperations.alarmControl is being set to 1 even if controller does not have alarm on board
- Unable to open "Set Patrol Read Properties" in MSM with 2008-iMR
- If VD is secured while reconstruction is going on does not stay secured once reconstruction is done.
- Allocate BBLog for iMR Initially during boot up
- When attempting to secure LD during RLM, receive option to secure LD, LD not secured (message incorrect/misleading.)
- Saved Release Note DataSLIB returning bad data as good data after host reboots
- Minimum Capacity needed for relearn is incorrect in 2208 MR FW
- Improve foreign config import for iMR with mixed JBOD/RAID settings
- Correct the error in copy back path smart errors path
- Defect fix for VD rebuild does not kick in and goes to foreign state after reboot
- Disconnect SCap during Shutdown/Hibernate only if pinned cache is not present
- spare pointer is incorrectly used in MR_CONFIG_DATA
- Fix For code analysis Defects Reported
- Change RAID controller FW bad battery warning message that comes up during POST.
- Patrol Read - no progress
- ECC/Medium/Unrecoverable read errors handling Enhancement
- FW halts when you have pinned cache and remove VD form the configuration.
- If the hotspare was spun down, the copy back after a drive failure wouldn't always start.
- Invalid target ID after new logical drive creation
- sync error stat for MRS
- CMDTool2 reports battery pack is missing on hot insertion
- Card Running iMR Machine Checks when Requesting Host Memory
- Infinite retry happens on Test Unit command when HDD didn't respond to TU command during the initialization.
- Virtual drive configurations go missing during firmware upgrade from 5.3 to 5.7, while running Consistency Check (CC), after two reboots
- Fix for the defect - 4k drives display wrong value of Coerced size.
- Write policy changed from Write-through (WT) to Write-back (WB) when the battery/Supercap is declared as bad
- Profile based VD creation path incorrectly showing protect VD/secure VD check box when user clicks on drive selection criteria
- HII cannot assign partial space less than 1 GB
- HII 03.03.04.00/Profile based configuration help issues
- HII 03.03.03.00/PKG 5/When creating an invalid argument in HII during VD creation and after correction, save is grayed out
- Hii failed to report error warning when config 2pds R10 with different drive capacity
- UCM - Virtual Drive Configuration summary does not report the "Interface Type"
- HII: Navigation issue from Enable Drive Security form
- HII does not allow user to use the remain free capacity to configure additional VD for R50/R10.
- HII failed to allow user to use the remains free capacity for R1 VD with 2 plus TB capacity.
- Hii enter black screen/timeout when user switching between fields/form sub_form to create R10 VD on PERC9 controller.
- Hii failed to report warning that inappropriate drives are picked to config R10 VD.
- New Field "package version" in Controller Management
- UCM Driver - unable to create an 8PD R5
- BBU information and properties are not displayed in HII browser for Perc9-H730P controller.
- HII Manage Foreign Configuration menu is not available when a foreign locked drive is present in the configuration
- UEFI System hang if controller FW is in fault state
- Not possible to probe a volume > 2Tb on Niwot raid card
- In WebBIOS, if BGI is suspended the vd progress info page shows it as CC progress until it is resumed
- Incompatible strip size convention in TB
- Change in product name for OEM 2208 ROMB design

This download is valid for the products listed below:

- Intel Integrated RAID Module RMS25CB040
- Intel Integrated RAID Module RMS25CB080
- Intel Integrated RAID Module RMS25PB040
- Intel Integrated RAID Module RMS25PB080
- Intel Integrated RAID Module RMT3CB080
- Intel Integrated RAID Module RMT3PB080
- Intel RAID Controller RS25AB080
- Intel RAID Controller RS25DB080
- Intel RAID Controller RS25NB008
- Intel RAID Controller RS25SB008
-

  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Related Iriver Drivers

Iriver H320 Firmware 1.27

Device Type: Firmware File Size: 2 MB Windows 9X ,Windows ME ,Windows NT ,Windows 2K ,Windows XP ,Windows 2003 ,Windows Vista ,Windows XP 64 bit ,Windows 2008 ,Windows Vista 64 bit ,Window

Install Driver

Iriver Story E-Book Reader Firmware 1.71

Device Type: Firmware File Size: 63.5 MB Windows XP ,Windows Vista ,Windows XP 64 bit ,Windows Vista 64 bit ,Windows 7 ,Windows 7 64 bit

Install Driver

Iriver iMP-1100 firmware 1.05

Device Type: Firmware File Size: 2 MB Windows 9X ,Windows ME ,Windows NT ,Windows 2K ,Windows XP ,Windows 2003 ,Windows Vista ,Windows XP 64 bit ,Windows 2008 ,Windows Vista 64 bit ,Window

Install Driver

Iriver T8 Player Firmware 1.18

Device Type: Firmware File Size: 19 MB Windows XP ,Windows Vista ,Windows XP 64 bit ,Windows Vista 64 bit ,Windows 7 ,Windows 7 64 bit

Install Driver

Iriver iFP-895 UMS Firmware 1.28b

Device Type: Firmware File Size: 1.5 MB OS Independent

Install Driver

Iriver E300 Player Firmware 1.05 (Europe Version)

Device Type: Firmware File Size: 54.5 MB Windows XP ,Windows Vista ,Windows XP 64 bit ,Windows Vista 64 bit ,Windows 7 ,Windows 7 64 bit

Install Driver

Iriver T6 Player Firmware 2.20

Device Type: Firmware File Size: 4.1 MB Windows XP ,Windows Vista ,Windows XP 64 bit ,Windows Vista 64 bit ,Windows 7 ,Windows 7 64 bit

Install Driver

Iriver E200 Player Firmware 1.17

Device Type: Firmware File Size: 34.5 MB Windows XP ,Windows Vista ,Windows XP 64 bit ,Windows Vista 64 bit ,Windows 7 ,Windows 7 64 bit

Install Driver

Iriver T9 Player Firmware 1.06

Device Type: Firmware File Size: 2.6 MB Windows XP ,Windows Vista ,Windows XP 64 bit ,Windows Vista 64 bit ,Windows 7 ,Windows 7 64 bit

Install Driver

Find Missing Drivers

© 2024 PCI-DB.com - PCI Database Replacement. All rights reserved.